Saturday, October 8, 2011

40kw Generating unit 4BTA3.9-G1-60Hz

generating sets
40kw generating sets 4BTA3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms40s
generating sets
40kw generating sets 4BTA3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms40s
Product Name:40kw generating sets -60Hz
Model:4BTA3.9-G1
Prime Power(kw/Kva):37/46
Standby Power(kw/Kva):40/50
Rated Current A:75
Open type Dimension(L*W*H) mm:1940*820*1490
Open type Weight Kg::950
Manufacturer:Cummins
Model:4BTA3.9-G1
Exhaust3.9
Continuous/StandbyKW):55/60
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:17
Fuel consumption g/kw.h :209
Fuel consumptionL/h:16
Lub-oil Capacity Litre 14.2
max oil temperature 121
Coolant Capacity Litre 19.2
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S35
Stamford Model BCI184H
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

40kw Generating units 4BTA3.9-G1-60Hz

Generating units
40kw Generating units 4BTA3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms40s
Generating units
40kw Generating units 4BTA3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms40s
Product Name:40kw generating sets -60Hz
Model:4BTA3.9-G1
Prime Power(kw/Kva):37/46
Standby Power(kw/Kva):40/50
Rated Current A:75
Open type Dimension(L*W*H) mm:1940*820*1490
Open type Weight Kg::950
Manufacturer:Cummins
Model:4BTA3.9-G1
Exhaust3.9
Continuous/StandbyKW):55/60
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:17
Fuel consumption g/kw.h :209
Fuel consumptionL/h:16
Lub-oil Capacity Litre 14.2
max oil temperature 121
Coolant Capacity Litre 19.2
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S35
Stamford Model BCI184H
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

100kva diesel genset

100kva diesel genset supplier
1, Cummins engine
2, Stamford/marathon alternator
3, Global warranty
4, OEM of Cummins

Specifications of Cummins 100kva diesel genset
Model:
SF110
Prime Power:
80kw/100kva
Standby Power:
88kw/110kva
Engine Brand:
Cummins
Engine Model:
6BT5.9-G2
Alternator Brand:
Stamford or Marathon
Alternator Model:
UCI274C
Frequency:
50Hz
Rated Voltage:
380V/220V (adjustable)
Rated Currency:
152AMP



Controller (Control panel) Brand: Deep Sea or Smartgen for 100kva diesel genset
(Digital and intelligent) LED Screen and touch Buttons’
Main Functions,
1- Display loading power, voltages, currencies, frequency, speed, temperatures, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Shut down when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc

Optional Accessories of 100kva diesel genset

1.
ATS (
Automatic Transfer switch);
Which can start the diesel generator when the main power is off; when the main power comes back, it will shut down generator.
And ATS have the function of AMF (automatic Main power failure)
2.
MCCB
(Molded case circuit breaker);
It can protect the loading machine and the diesel generator.
3.
Battery
charger
(float charger);
When the generator hasn’t been used for a long time, the batteries will be no power, in that way, you can’t start the generator. But the battery charger can charge the batteries from main power.
4.
Extra daily fuel tank
;
It will be requested while the base fuel tank capacity is not enough for daily fuel consumption.
5.
Paralleling system
;
This system can make several generators work together and automatically distribute the load according to set.
6.
Remote Control Panel
;
Which can control the generator by computer, if use a RS484 or RS232 digital cable to connect the generator to the computer.
7.
Water separate (additional cooling system);
If the ambient temperature is too high, it will be harmful to the diesel generator. Fan and water cooling is not enough for radiate. The water separate system is much better for cooling, and the life of generator will be much longer.
8.
Spare Parts of Cummins engine;
All the spare parts of each Cummins engine are supplied at very competitive price.

40kw High Frequency Generator

1.40kw High frequency generator
2.RF /HF generator
3.CE standard components
4.From 5KW-100KW
5.JYE- 18 years experience
High frequency generator

The radio frequency generator is a core component for dielectric heating. It applies
380V power, 50Hz AC. It generates a high frequency of 6.78MHz or 13.56MHz or
27.12MHz, which is put on the work-piece through a matching device. The electric
field penetrates the medium and acts on the glue molecules selectively. The glue
molecules were polarized and move in high speed, then it gets heat acutely and
become solidified. At present, the high frequency dielectric heating are
used for
production of curved plywood furniture, edge glued panel, assembled wooden door,man-made wood, furniture frame, sound box, container floor, and work-pieces of musical instrument
. Dielectric heating by the high frequency as a modern solution
of wood working will become more and more popular in the field of furniture
and its related production. Our HF generators have been tested by national authority
organization in accordance with national standard of radiation.

We also supply other machine:
1.
HIGH FREQUENCY CURVED PLYWOOD PRESS: P
lywood, MDF, HDF bending: office chair, sofa, bed elements, musical instrument and others
2.
HIGH FREQUENCY FRAME ASSEMBLY MACHINE (FOR 90 DEGREE ANGLE SOLID FRAME ASSEMBLING)
3.
HIGH FREQUENCY CABINET DOOR ASSEMBLER (FOR 45 DEGREE ANGLE PHOTO FRAME, CABINET DOOR FRAME ASSEMBLING
Solid wood frame assembling: door, window, photo frame, cabinet-door and other frame assembling
4.
HIGH FREQUENCY VACUUM DRYER (FOR WOOD DRYING)
HF heating in vacuum condition. More uniform and 10 times faster than steam. No crack, bending, color-changing problem. Worm killing. No population (no boiler)
5. HIGH FREQUENCY EDGE GLUER (FOR FINGER JOINT BOARD JOINING)

40kw LOVOL diesel generator

Lovol diesel generator
1/CE certificate
2/ISO9001:2008 certificate
3/more than 10 years manufacturing experience.
Lovol diesel generator
1/Output:100kw
2/Engine details: LOVOL series
3/Alternator details: Stamford series, Marathon series, Lerysomer series Kaijieli and so on.
4/Water-cooled
5/8hrs operation base tank
6/Key start/auto start
7/Sound-proof/weather-proof canopy is optional
8/230/440V AC, 50HZ/60HZ,0.8PF three-phase and four wires alternating current output
9/Frequency: <3%
10/Frequency at stable state: <0.5%
11/ Frequency deviation at instantaneous state: ≤+10%
12/Frequency return time: ≤3s
13/Voltage deviation at stable state: ≤+1%
14/Voltage deviation at instantaneous state: ≤+20%
15/Voltage return time: ≤4s
16/Voltage modulation: ≤0.3%
17/Standard configuration of gensets:
a) Engine: Cummins series diesel engine
b) Engine type: water-cooled, in line four-stoke, direct injection
c) Alternator: Marathon brushless alternator
18/Control system:
a)Automatic alarm system: the unit has the acoustic-optics.

40kw Marine generating sets 4BTA3.9-GM47-50Hz

Marine generating sets
40kw Marine generating sets 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
Marine generating sets
40kw Marine generating sets 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms40pm
Product Name:40kw Marine generating sets -50Hz
Model:4BTA3.9-GM47
Prime Power(kw/Kva):40/50
Standby Power(kw/Kva):44/55
Rated Current A:72
Open type Dimension(L*W*H) mm:1500*750*1320
Open type Weight Kg::1000
Manufacturer:Cummins
Model:4BTA3.9-GM47
Exhaust3.9
Continuous/StandbyKW):47/52
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:16
Governor :E
Fuel consumption g/kw.h :209
Fuel consumptionL/h:11.9
Lub-oil Capacity Litre 10.9
max oil temperature 121
Coolant Capacity Litre 16.9
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

40kw diesel generator

40kw diesel generator Cummins diesel engine accessories complete the relevant,stocked.

40kw diesel generator

40kw diesel generator picture performance parameters



keywords
generating sets
Title
25KVA generating sets 4B3.9-G1-50Hz
use
Land
Frequency Hz
50Hz
YK Model
kms25PV
Product Name
25KVA generating sets -50Hz
Model
4B3.9-G1
Prime Power(kw/Kva)
20/25
Standby Power(kw/Kva)
22/27
Rated Current A
36
Open type Dimension(L*W*H) mm
1700*750*1230
Open type Weight Kg
850
Soundproof Dimension(L*W*H) mm

Soundproof Weight Kg

Manufacturer
Cummins
Model
4B3.9-G1
Exhaust
3.9
Continuous/Standby(KW)
24/27
Aspiration & Cooling
Natural
Cylinders Capacity Lt
4
Cylinders & Build
In line
Speed RPM
1500
Bore & Stroke mm×mm
102×120
Compression Ratio
18.2
Governor
Machinery
Fuel consumption g/kw.h
229
Fuel consumption(L/h)
16
Lub-oil Capacity Litre
9.5
max oil temperature (°C)
121
Coolant Capacity Litre

Cooling method

Max intake resistance(kPa)
6.2
Max exhaust back pressure
10
Flue gas temperature (°C)
502
Thermostat(°C)
82-93
Manufacturer

Leroy Somer Model

Stamford Model

Excitation

Output Voltage V
400/230
Steady Voltage Adjusting Range
±1%
Insulation
H
Protection
IP23
Ventilation cooling capacity(1/s)
216
Rated capacity(V)
24

Common Model generator
product
diesel engine model
20kw generator-50Hz
4B3.9-G2
80kw generator-50Hz
6BT5.9-G2
145kw generator-50Hz
6CTA8.3-G2
200kw generator-50Hz
6LTAA8.9-G2
200kw generator-50Hz
MTA11-G2A
200kw generator-50Hz
NT855-GA
400kw generator-50Hz
QSX15-G8
305kw generator-50Hz
KTA19-G2
600kw generator-50Hz
QSK23-G2
520kw generator-50Hz
VTA28-G5
752kw generator-50Hz
QST30-G3
512kw generator-50Hz
KT38-G
1180kw generator-50Hz
KTA50-G5

other generator picture



40kw diesel generator package size
40kw diesel generator
length

(mm)
40kw diesel generator
width

(mm)
40kw diesel generator
height

(mm)
40kw diesel generator
Weight

(kg)



40kw diesel generator

1: reasonable price and best quality
2: one of the biggest suppliers in China
3: first-class and lasting service














DIESEL
GENERATOR
SET





Genset Model
HFC-40GF
Prime power (KW/KVA)
40/50
Standby power (KW/KVA)
45/55
Rated voltage(V)
230/400
Rated current (A)
72
Frequency(Hz)
50
Rated Rotary Speed (RPM)
1500
Power Factor
0.8(lag)
Fuel consumption.(g/kw.h)
210
Starting Method
24 DC
Engine
Cummins-4BTA3.9-G2
Cylinder Qty.
4 cylinder,Vertical in line, four stroke
Bore(mm) *Stroke (mm)
102*120
Compression rate
17.5:1
Cooling Method
water-cooled
Lubricant Capacity(L)
11
Intake Method
supercharged
Alternator
SAl-40
Power (KW/KVA)
40/50
Exciting Method
Brushless,
Insulation grade
H
Protection grade
IP22
Steady Timing Ratio(%)
±5
Instant Timing Ratio(%)
±7
Spend Stabilization Time(S)
< 5
Fluctuating rate of frequency(%)
±0.5
Voltage adjustment mode
AVR

40kw gensets 4BTA3.9-G1-60Hz

generating sets
40kw generating sets 4BTA3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
generating sets
40kw generating sets 4BTA3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms40s
Product Name:40kw generating sets -60Hz
Model:4BTA3.9-G1
Prime Power(kw/Kva):37/46
Standby Power(kw/Kva):40/50
Rated Current A:75
Open type Dimension(L*W*H) mm:1940*820*1490
Open type Weight Kg::950
Manufacturer:Cummins
Model:4BTA3.9-G1
Exhaust3.9
Continuous/StandbyKW):55/60
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:17
Fuel consumption g/kw.h :209
Fuel consumptionL/h:16
Lub-oil Capacity Litre 14.2
max oil temperature 121
Coolant Capacity Litre 19.2
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S35
Stamford Model BCI184H
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

40w ac generator (FSW-50AM)

Output:40W
Supply Voltage:12V+- O.5V
Supply Current:4A
Charge Voltage:14V+-1V
Change Current:1-2.5A
The series’ generator is designed to supply emergency power manually. It can be used to charge communication radio station or charge storage battery in very short time. It is adaptable for kinds of wild working environments, by multi-optional installation with folding supporter, tripod. It is widely used in many fields such as military troops, public security, geological survey, etc. and now enjoys popularity in European, American and South- East Asian countries.
The generator can work efficiently with advantages of multi-protection electric circuits, stable output, convenient carry. Furthermore, the generator enjoys free maintenance and waterproof.

4105 Series natural gas generator sets

1)40kw series natural gas generator sets
2)50hz
3)Three-phase
4)1500rpm

Unit Model
YXF40kW-NG
Gas Model
T4105Z
Fuel type
Natural gas
Generator Model
DLI2C24
Type
In-line, 4-cylinder, four-stroke, spark plugs, ignition, water-cooled, Turbocharged, electronic speed control
Bore × stroke mm
105×125
DisplacementL
4.33
Compression ratio
101
Electric ignition system
Ignition Power
CPU digital electrical ignition system or distributor ignition system
Ignition sequence
1-3-4-2Cylinder order from free
Ignition mode
Electric spark plug ignition
Rated speedr/min
1500
Rated PowerkW
40
Rated CurrentA
72.2
Rated voltageV
400
Regulator approach
Automatic
Excitation mode
Brushless
Dimensions(L×W×H)(mm)
2190×700×1540
Net Quality(kg)
1250

4105 Series natural gas generator sets

1)40kw series natural gas generator sets
2)50hz
3)Three-phase
4)1500rpm

Unit Model
YXF40kW-NG
Gas Model
T4105Z
Fuel type
Natural gas
Generator Model
DLI2C24
Type
In-line, 4-cylinder, four-stroke, spark plugs, ignition, water-cooled, Turbocharged, electronic speed control
Bore × stroke mm
105×125
DisplacementL
4.33
Compression ratio
101
Electric ignition system
Ignition Power
CPU digital electrical ignition system or distributor ignition system
Ignition sequence
1-3-4-2Cylinder order from free
Ignition mode
Electric spark plug ignition
Rated speedr/min
1500
Rated PowerkW
40
Rated CurrentA
72.2
Rated voltageV
400
Regulator approach
Automatic
Excitation mode
Brushless
Dimensions(L×W×H)(mm)
2190×700×1540
Net Quality(kg)
1250

410kw Cummins diesel generating sets KTA19-G3-50Hz

Cummins diesel generating sets
410kw Cummins diesel generating sets KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
Cummins diesel generating sets
410kw Cummins diesel generating sets KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms410s
Product Name:410kw generating sets -50Hz
Model:KTA19-G3
Prime Power(kw/Kva):350/438
Standby Power(kw/Kva):410/513
Rated Current A:648
Open type Dimension(L*W*H) mm:3400*1266*1830
Open type Weight Kg::3800
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Manufacturer
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

100kva power genset

100kva power genset supplier
1, Cummins engine
2, Stamford/marathon alternator
3, Global warranty
4, OEM of Cummins

Specifications of Cummins 100kva power genset
Model:
SF110
Prime Power:
80kw/100kva
Standby Power:
88kw/110kva
Engine Brand:
Cummins
Engine Model:
6BT5.9-G2
Alternator Brand:
Stamford or Marathon
Alternator Model:
UCI274C
Frequency:
50Hz
Rated Voltage:
380V/220V (adjustable)
Rated Currency:
152AMP



Controller (Control panel) Brand: Deep Sea or Smartgen for 100kva power genset
(Digital and intelligent) LED Screen and touch Buttons’
Main Functions,
1- Display loading power, voltages, currencies, frequency, speed, temperatures, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Shut down when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc

Optional Accessories of 100kva power genset

1.
ATS (
Automatic Transfer switch);
Which can start the diesel generator when the main power is off; when the main power comes back, it will shut down generator.
And ATS have the function of AMF (automatic Main power failure)
2.
MCCB
(Molded case circuit breaker);
It can protect the loading machine and the diesel generator.
3.
Battery
charger
(float charger);
When the generator hasn’t been used for a long time, the batteries will be no power, in that way, you can’t start the generator. But the battery charger can charge the batteries from main power.
4.
Extra daily fuel tank
;
It will be requested while the base fuel tank capacity is not enough for daily fuel consumption.
5.
Paralleling system
;
This system can make several generators work together and automatically distribute the load according to set.
6.
Remote Control Panel
;
Which can control the generator by computer, if use a RS484 or RS232 digital cable to connect the generator to the computer.
7.
Water separate (additional cooling system);
If the ambient temperature is too high, it will be harmful to the diesel generator. Fan and water cooling is not enough for radiate. The water separate system is much better for cooling, and the life of generator will be much longer.
8.
Spare Parts of Cummins engine;
All the spare parts of each Cummins engine are supplied at very competitive price.

410kw Cummins generator KTA19-G3-60Hz

Cummins generating
410kw Cummins generating KTA19-G3-60Hz
use:Land
Cummins generating
410kw Cummins generating KTA19-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms410p
Product Name:410kw generating sets -60Hz
Model:KTA19-G3
Prime Power(kw/Kva):410/512
Standby Power(kw/Kva):451/563
Rated Current A:788
Open type Dimension(L*W*H) mm:3200*1310*1850
Open type Weight Kg::4250
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA47.2M7
Excitation:Brushless, AVR
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

410kw Cummins generators KTA19-G3-50Hz

generating sets
410kw generating sets KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
generating sets
410kw generating sets KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms410s
Product Name:410kw generating sets -50Hz
Model:KTA19-G3
Prime Power(kw/Kva):350/438
Standby Power(kw/Kva):410/513
Rated Current A:648
Open type Dimension(L*W*H) mm:3400*1266*1830
Open type Weight Kg::3800
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Manufacturer
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

410kw Marine Cummins generating set KTA19-G3M-50Hz

Marine generating sets
410kw Marine generating sets KTA19-G3M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms410sm
Marine generating sets
410kw Marine generating sets KTA19-G3M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms410sm
Product Name:410kw Marine generating sets -50Hz
Model:KTA19-G3M
Prime Power(kw/Kva):350/438
Standby Power(kw/Kva):410/573
Rated Current A:630
Open type Dimension(L*W*H) mm:3100*1266*1830
Open type Weight Kg::3400
Manufacturer:Cummins
Model:KTA19-G3M
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:93
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

410kw diesel generator (CE approved)

410kw diesel generator supplier
1,Global warranty
2,16kw to 1200kw
3,OEM of Cummins
4,410kw diesel generator at best price
Specifications of Cummins 410kw diesel generator (CE approved)
Diesel generator of Cummins engine couple with Stamford alternator
Controller (Control panel) Brand: Deep Sea or Smartgen for Cummins diesel generator
(Digital and intelligent) LED Screen and touch Buttons’for Cummins diesel generator
Diesel generator Combination
Standby Power
Rated Power
Power for Engine and Alternator
Engine
Alternator
kva
kw
kva
kw
Engine
Alternator
4B3.9-G2
PI144D
22
18
20
16
24kw/30kva
16kw/20kva
4B3.9-G2
PI144E
28
22
25
20
24kw/30kva
20kw/25kva
4B3.9-G2
PI144F
30
24
27
22
24kw/30kva
22kw/27.5kva
4BT3.9-G2
PI144G
33
26
30
24
36kw/40kva
24kw/30kva
4BT3.9-G2
PI144H
39
31
35
28
36kw/40kva
28kw/35kva
4BT3.9-G2
PI144J
44
35
40
32
36kw/40kva
32kw/40kw
4BTA3.9-G2
PI144K
47
37
43
34
50kw/62.5kva
34kw/42.5kva
4BTA3.9-G2
UCI224D
55
44
50
40
50kw/62.5kva
40kw/50kva
4BTA3.9-G2
UCI224E
62
50
56
45
50kw/62.5kva
48kw/60kva
6BT5.9-G2
UCI224F
80
64
73
58
87kw/109kva
58kw/72.5kva
6BT5.9-G2
UCI224G
94
75
85
68
87kw/109kva
68kw/85kva
6BT5.9-G2
UCI274C
103
83
94
75
87kw/109kva
80kw/100kva
6BTA5.9-G2
UCI274C
110
88
100
80
110kw/135kva
80kw/100kva
6BTA5.9-G2
UCI274D
124
99
113
90
110kw/135kva
91.2kw/114kva
6BTAA5.9-G2
UCI274E
138
110
125
100
120kw/150kva
112kw/140kva
6CTA8.3-G2
UCI274E
154
123
140
112
163kw/204kva
112kw/140kva
6CTA8.3-G2
UCI274F
176
141
160
128
163kw/204kva
128kw/160kva
6CTA8.3-G2
UCI274G
200
160
182
146
163kw/204kva
145.6kw/182kva
6CTAA8.3-G2
UCI274H
220
176
200
160
200kw/250kva
160kw/200kva
6LTAA8.9-G2
UCDI274J
253
202
230
184
235kw/294kva
184kw/230kva
6LTAA8.9-G2
UCDI274K
275
220
250
200
220kw/240kva
200kw/250kva
NT855-GA
UCDI274K
275
220
250
200
231kw/289kva
200kw/250kva
NTA855-G1A
HCI444D
313
250
275
220
261kw/326kva
240kw/300kva
NTA855-G1B
HCI444D
330
264
300
240
284kw/355kva
240kw/300kva
NTA855-G1B
HCI444ES
344
275
313
250
284kw/355kva
260kw/325kva
NTA855-G2A
HCI444E
378
303
344
275
313kw/391kva
280kw/350kva
NTA855-G4
HCI444E
385
308
350
280
317kw/391kva
280kw/350kva
NTA855-G7
HCI444FS
413
330
375
300
343kw429kva
304kw/380kva
NTA855-G7A
HCI444F
440
352
400
320
360kw/450kva
320kw/400kva
KTA19-G2
HCI444F
440
352
400
320
336kw/420kva
320kw/400kva
KTA19-G3
HCI 544C
495
396
450
360
403kw/504kva
360kw/450kva
KTA19-G4
HCI544D
550
440
500
400
448kw/560kva
400kw/500kva
KTA19-G5
HCI544E
578
462
525
420
470kw/588kva
480kw/600kva
KTA19-G8
HCI544E
649
519
590
472
510kw/640kva
480kw/600kva
KTAA19-G6
HCI544E
633
506
575
460
520kw/650kva
480kw/600kva
KTAA19-G6A
HCI544E
660
528
600
480
540kw/675kva
480kw/600kva
KTAA19-G6A
HCI544F
688
550
625
500
540kw/675kva
536kw/670kva
QSKTAA19-G3
HCI544F
688
550
625
500
574kw/718kva
536kw/670kva
KT38-G
HCI544F
688
550
625
500
679kw/849kva
536kw/670kva
KT38-GA
LVI634B
798
638
725
580
640kw/800kva
600kw/750kva
KTA38-G2
LVI634B
825
660
750
600
664kw/830kva
600kw/750kva
KTA38-G2A
HCI634G
891
713
810
648
813kw/1016kva
648kw/810kva
KTA38-G2A
LVI634D
1001
801
910
728
813kw/1016kva
728kw/910kva
KTA38-G5
HCI634J
1100
880
1000
800
880kw/1100kva
800kw/1000kva
KTA38-G9A
HCI634K
1221
977
1110
888
1070kw/1337kva
888kw/1110kva
KTA38-G9A
PI734A
1348
1078
1225
980
1070kw/1337kva
980kw/1225kva
KTA50-G3
PI734A
1348
1078
1225
980
1097kw/1371kva
980kw/1225kva
KTA50-G8
PI734B
1496
1197
1360
1088
1200kw/1500kva
1088kw/1360kva
KTA50-GS8
PI734B
1581
1265
1438
1150
1287kw/1609kva
1204kw/1505kva

413KVA Cummins generator set NTA855-G3-60Hz

Cummins generator set
413KVA Cummins generator set NTA855-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms413SV
Cummins generator set
413KVA Cummins generator set NTA855-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms413SV
Product Name:413KVA generating sets -60Hz
Model:NTA855-G3
Prime Power(kw/Kva):300/375
Standby Power(kw/Kva):330/413
Rated Current A:541
Open type Dimension(L*W*H) mm:3200*1310*1850
Open type Weight Kg::4250
Manufacturer:Cummins
Model:NTA855-G3
Exhaust14
Continuous/StandbyKW):317/351
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :140×152
Compression Ratio:16.5
Governor :EFC
Fuel consumption g/kw.h :201
Fuel consumptionL/h:62
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 485
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA47.2VS2
Excitation:Brushless, AVR
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)486
Rated capacityV)24

413KVA Marine Cummins generating set KTA19-G2M-50Hz

Marine Cummins generating set
413KVA Marine Cummins generating set KTA19-G2M-50Hz
use:Marine
Frequency Hz:50Hz
Marine Cummins generating set
413KVA Marine Cummins generating set KTA19-G2M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms413SVM
Product Name:413KVA Marine generating sets -50Hz
Model:KTA19-G2M
Prime Power(kw/Kva):300/375
Standby Power(kw/Kva):330/413
Rated Current A:541
Open type Dimension(L*W*H) mm:3100*1266*1830
Open type Weight Kg::3300
Manufacturer:Cummins
Model:KTA19-G2M
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:76
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93

Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

413KVA Marine Generators KTA19-G2M-50Hz

Marine Generators
413KVA Marine Generators KTA19-G2M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms413SVM
Marine Generators
413KVA Marine Generators KTA19-G2M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms413SVM
Product Name:413KVA Marine generating sets -50Hz
Model:KTA19-G2M
Prime Power(kw/Kva):300/375
Standby Power(kw/Kva):330/413
Rated Current A:541
Open type Dimension(L*W*H) mm:3100*1266*1830
Open type Weight Kg::3300
Manufacturer:Cummins
Model:KTA19-G2M
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:76
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

413KVA Marine generating sets KTA19-G2M-50Hz

Marine generating sets
413KVA Marine generating sets KTA19-G2M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms413SVM
Marine generating sets
413KVA Marine generating sets KTA19-G2M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms413SVM
Product Name:413KVA Marine generating sets -50Hz
Model:KTA19-G2M
Prime Power(kw/Kva):300/375
Standby Power(kw/Kva):330/413
Rated Current A:541
Open type Dimension(L*W*H) mm:3100*1266*1830
Open type Weight Kg::3300
Manufacturer:Cummins
Model:KTA19-G2M
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:76
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

413KVA generating sets NTA855-G3-60Hz

generating sets
413KVA generating sets NTA855-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms413SV
generating sets
413KVA generating sets NTA855-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms413SV
Product Name:413KVA generating sets -60Hz
Model:NTA855-G3
Prime Power(kw/Kva):300/375
Standby Power(kw/Kva):330/413
Rated Current A:541
Open type Dimension(L*W*H) mm:3200*1310*1850
Open type Weight Kg::4250
Manufacturer:Cummins
Model:NTA855-G3
Exhaust14
Continuous/StandbyKW):317/351
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :140×152
Compression Ratio:16.5
Governor :EFC
Fuel consumption g/kw.h :201
Fuel consumptionL/h:62
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 485
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA47.2VS2
Excitation:Brushless, AVR
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)486
Rated capacityV)24

41KVA Cummins diesel generating sets 4BT3.9-G1-60Hz

generating sets
41KVA generating sets 4BT3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
generating sets
41KVA generating sets 4BT3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms41SV
Product Name:41KVA generating sets -60Hz
Model:4BT3.9-G1
Prime Power(kw/Kva):30/38
Standby Power(kw/Kva):33/41
Rated Current A:50
Open type Dimension(L*W*H) mm:1900*810*1490
Open type Weight Kg::900
Manufacturer:Cummins
Model:4BT3.9-G1
Exhaust3.9
Continuous/StandbyKW):36/40
Aspiration & Cooling:Turbo
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:18.2
Fuel consumption g/kw.h :214
Fuel consumptionL/h:16
Lub-oil Capacity Litre 9.5
max oil temperature 121
Coolant Capacity Litre 19
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S25
Stamford Model BCI184G
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

100kw 125kva diesel generator set

100kw 125kva diesel generator set,Cummins diesel engine accessories complete the relevant,stocked.

100kw 125kva diesel generator set

100kw 125kva diesel generator set picture performance parameters



keywords
generating sets
Title
25KVA generating sets 4B3.9-G1-50Hz
use
Land
Frequency Hz
50Hz
YK Model
kms25PV
Product Name
25KVA generating sets -50Hz
Model
4B3.9-G1
Prime Power(kw/Kva)
20/25
Standby Power(kw/Kva)
22/27
Rated Current A
36
Open type Dimension(L*W*H) mm
1700*750*1230
Open type Weight Kg
850
Soundproof Dimension(L*W*H) mm

Soundproof Weight Kg

Manufacturer
Cummins
Model
4B3.9-G1
Exhaust
3.9
Continuous/Standby(KW)
24/27
Aspiration & Cooling
Natural
Cylinders Capacity Lt
4
Cylinders & Build
In line
Speed RPM
1500
Bore & Stroke mm×mm
102×120
Compression Ratio
18.2
Governor
Machinery
Fuel consumption g/kw.h
229
Fuel consumption(L/h)
16
Lub-oil Capacity Litre
9.5
max oil temperature (°C)
121
Coolant Capacity Litre

Cooling method

Max intake resistance(kPa)
6.2
Max exhaust back pressure
10
Flue gas temperature (°C)
502
Thermostat(°C)
82-93
Manufacturer

Leroy Somer Model

Stamford Model

Excitation

Output Voltage V
400/230
Steady Voltage Adjusting Range
±1%
Insulation
H
Protection
IP23
Ventilation cooling capacity(1/s)
216
Rated capacity(V)
24

Common Model generator
product
diesel engine model
20kw generator-50Hz
4B3.9-G2
80kw generator-50Hz
6BT5.9-G2
145kw generator-50Hz
6CTA8.3-G2
200kw generator-50Hz
6LTAA8.9-G2
200kw generator-50Hz
MTA11-G2A
200kw generator-50Hz
NT855-GA
400kw generator-50Hz
QSX15-G8
305kw generator-50Hz
KTA19-G2
600kw generator-50Hz
QSK23-G2
520kw generator-50Hz
VTA28-G5
752kw generator-50Hz
QST30-G3
512kw generator-50Hz
KT38-G
1180kw generator-50Hz
KTA50-G5

other generator picture



100kw 125kva diesel generator set package size
100kw 125kva diesel generator set
length

(mm)
100kw 125kva diesel generator set
width

(mm)
100kw 125kva diesel generator set
height

(mm)
100kw 125kva diesel generator set
Weight

(kg)


41KVA Cummins generator sets 4BT3.9-G1-50Hz

Cummins generator sets
41KVA Cummins generator sets 4BT3.9-G1-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms41SV
Cummins generator sets
41KVA Cummins generator sets 4BT3.9-G1-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms41SV
Product Name:41KVA generating sets -50Hz
Model:4BT3.9-G1
Prime Power(kw/Kva):30/37.5
Standby Power(kw/Kva):33/41
Rated Current A:50
Open type Dimension(L*W*H) mm:1900*810*1490
Open type Weight Kg::900
Manufacturer:Cummins
Model:4BT3.9-G1
Exhaust3.9
Continuous/StandbyKW):36/40
Aspiration & Cooling:Turbo
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:18.2
Fuel consumption g/kw.h :214
Fuel consumptionL/h:16
Lub-oil Capacity Litre 9.5
max oil temperature 121
Coolant Capacity Litre 19
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S15
Stamford Model BCI184H
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

41KVA Cummins generator unit 4BT3.9-G1-60Hz

Cummins generator unit
41KVA Cummins generator unit 4BT3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
Cummins generator unit
41KVA Cummins generator unit 4BT3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms41SV
Product Name:41KVA generating sets -60Hz
Model:4BT3.9-G1
Prime Power(kw/Kva):30/38
Standby Power(kw/Kva):33/41
Rated Current A:50
Open type Dimension(L*W*H) mm:1900*810*1490
Open type Weight Kg::900
Manufacturer:Cummins
Model:4BT3.9-G1
Exhaust3.9
Continuous/StandbyKW):36/40
Aspiration & Cooling:Turbo
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:18.2
Fuel consumption g/kw.h :214
Fuel consumptionL/h:16
Lub-oil Capacity Litre 9.5
max oil temperature 121
Coolant Capacity Litre 19
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S25
Stamford Model BCI184G
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

41KVA generating set 4BT3.9-G1-60Hz

generating set
41KVA generating set 4BT3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms41SV
generating set
41KVA generating set 4BT3.9-G1-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms41SV
Product Name:41KVA generating sets -60Hz
Model:4BT3.9-G1
Prime Power(kw/Kva):30/38
Standby Power(kw/Kva):33/41
Rated Current A:50
Open type Dimension(L*W*H) mm:1900*810*1490
Open type Weight Kg::900
Manufacturer:Cummins
Model:4BT3.9-G1
Exhaust3.9
Continuous/StandbyKW):36/40
Aspiration & Cooling:Turbo
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:18.2
Fuel consumption g/kw.h :214
Fuel consumptionL/h:16
Lub-oil Capacity Litre 9.5
max oil temperature 121
Coolant Capacity Litre 19
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S25
Stamford Model BCI184G
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

Friday, October 7, 2011

420kw Cummins generating set KTA19-G3-60Hz

Cummins generating set
420kw Cummins generating set KTA19-G3-60Hz
use:Land
Cummins generating set
420kw Cummins generating set KTA19-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms420p
Product Name:420kw generating sets -60Hz
Model:KTA19-G3
Prime Power(kw/Kva):420/525
Standby Power(kw/Kva):462/578
Rated Current A:788
Open type Dimension(L*W*H) mm:3650*1350*1970
Open type Weight Kg::3600
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Manufacturer
Leroy Somer ModelLSA47.2 M7
Stamford Model HCI544C
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

422kw Cummins gensets KTA19-G3-60Hz

Cummins gensets
422kw Cummins gensets KTA19-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms422s
Cummins gensets
422kw Cummins gensets KTA19-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms422s
Product Name:422kw generating sets -60Hz
Model:KTA19-G3
Prime Power(kw/Kva):384/480
Standby Power(kw/Kva):422/528
Rated Current A:688
Open type Dimension(L*W*H) mm:3650*1350*1970
Open type Weight Kg::3600
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Leroy Somer ModelLSA47.2 M7
Stamford Model HCI444F
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

422kw generating sets KTA19-G3-60Hz

generating sets
422kw generating sets KTA19-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms422s
generating sets
422kw generating sets KTA19-G3-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms422s
Product Name:422kw generating sets -60Hz
Model:KTA19-G3
Prime Power(kw/Kva):384/480
Standby Power(kw/Kva):422/528
Rated Current A:688
Open type Dimension(L*W*H) mm:3650*1350*1970
Open type Weight Kg::3600
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Leroy Somer ModelLSA47.2 M7
Stamford Model HCI444F
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

423KVA Cummins generator sets KTA19-G2-50Hz

Cummins generator sets
423KVA Cummins generator sets KTA19-G2-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms423SV
Cummins generator sets
423KVA Cummins generator sets KTA19-G2-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms423SV
Product Name:423KVA generating sets -50Hz
Model:KTA19-G2
Prime Power(kw/Kva):305/381
Standby Power(kw/Kva):338/423
Rated Current A:541
Open type Dimension(L*W*H) mm:3200*1310*1850
Open type Weight Kg::4250
Soundproof Dimension(L*W*H) mm:4500*1550*2150
Soundproof Weight Kg:4800
Manufacturer:Cummins
Model:KTA19-G2
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA47.2S4
Excitation:Brushless, AVR
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

423KVA Cummins power KTA19-G2-50Hz

generating sets
423KVA generating sets KTA19-G2-50Hz
use:Land
Frequency Hz:50Hz
generating sets
423KVA generating sets KTA19-G2-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms423SV
Product Name:423KVA generating sets -50Hz
Model:KTA19-G2
Prime Power(kw/Kva):305/381
Standby Power(kw/Kva):338/423
Rated Current A:541
Open type Dimension(L*W*H) mm:3200*1310*1850
Open type Weight Kg::4250
Soundproof Dimension(L*W*H) mm:4500*1550*2150
Soundproof Weight Kg:4800
Manufacturer:Cummins
Model:KTA19-G2
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA47.2S4
Excitation:Brushless, AVR
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

42KVA Cummins diesel generating set 4BT3.9-G1-50Hz

Cummins diesel generating set
42KVA Cummins diesel generating set 4BT3.9-G1-50Hz
use:Land
Frequency Hz:50Hz
Cummins diesel generating set
42KVA Cummins diesel generating set 4BT3.9-G1-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms42SV
Product Name:42KVA generating sets -50Hz
Model:4BT3.9-G1
Prime Power(kw/Kva):30/38
Standby Power(kw/Kva):33/42
Rated Current A:50
Open type Dimension(L*W*H) mm:1800*780*1230
Open type Weight Kg::900
Manufacturer:Cummins
Model:4BT3.9-G1
Exhaust3.9
Continuous/StandbyKW):36/40
Aspiration & Cooling:Turbo
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:18.2
Governor :Machinery
Fuel consumption g/kw.h :214
Fuel consumptionL/h:16
Lub-oil Capacity Litre 9.5
max oil temperature 121
Coolant Capacity Litre 19
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

42KVA Cummins diesel generator 4B3.9-G2-60Hz

Cummins diesel generator
42KVA Cummins diesel generator 4B3.9-G2-60Hz
use:Land
Frequency Hz:60Hz
Cummins diesel generator
42KVA Cummins diesel generator 4B3.9-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms42PV
Product Name:42KVA generating sets -60Hz
Model:4B3.9-G2
Prime Power(kw/Kva):34/42
Standby Power(kw/Kva):38/47
Rated Current A:54
Open type Dimension(L*W*H) mm:1730*710*1200
Open type Weight Kg::680
Manufacturer:Cummins
Model:4B3.9-G2
Exhaust3.9
Continuous/StandbyKW):24/27
Aspiration & Cooling:Turbo
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:18.2
Governor :E
Fuel consumption g/kw.h :200
Fuel consumptionL/h:16
Lub-oil Capacity Litre 9.5
max oil temperature 121
Coolant Capacity Litre 19
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA42.2M7
Excitation:Brushless, AVR
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

100kw Cummins generator set 6BTAA5.9-G-50Hz

generating sets
100kw generating sets 6BTAA5.9-G-50Hz
use:Land
Frequency Hz:50Hz
generating sets
100kw generating sets 6BTAA5.9-G-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms100s
Product Name:100kw generating sets -50Hz
Model:6BTAA5.9-G
Prime Power(kw/Kva):90/113
Standby Power(kw/Kva):100/125
Rated Current A:162
Open type Dimension(L*W*H) mm:2353*820*1300
Open type Weight Kg::1492
Manufacturer:Cummins
Model:6BTAA5.9-G
Exhaust5.9
Continuous/StandbyKW):120/132
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:17.5
Fuel consumption g/kw.h :210
Fuel consumptionL/h:32
Lub-oil Capacity Litre 16.4
max oil temperature 121
Coolant Capacity Litre 25.1
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 510
Thermostat82-93
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

42KVA Generating unit 4B3.9-G2-60Hz

Generating unit
42KVA Generating unit 4B3.9-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms42PV
Generating unit
42KVA Generating unit 4B3.9-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms42PV
Product Name:42KVA generating sets -60Hz
Model:4B3.9-G2
Prime Power(kw/Kva):34/42
Standby Power(kw/Kva):38/47
Rated Current A:54
Open type Dimension(L*W*H) mm:1730*710*1200
Open type Weight Kg::680
Manufacturer:Cummins
Model:4B3.9-G2
Exhaust3.9
Continuous/StandbyKW):24/27
Aspiration & Cooling:Turbo
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:18.2
Governor :E
Fuel consumption g/kw.h :200
Fuel consumptionL/h:16
Lub-oil Capacity Litre 9.5
max oil temperature 121
Coolant Capacity Litre 19
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA42.2M7
Excitation:Brushless, AVR
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

437KVA Cummins diesel generating sets KTA19-G2-60Hz

Cummins diesel generating sets
437KVA Cummins diesel generating sets KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
Cummins diesel generating sets
437KVA Cummins diesel generating sets KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms437PV
Product Name:437KVA generating sets -60Hz
Model:KTA19-G2
Prime Power(kw/Kva):350/437
Standby Power(kw/Kva):385/480
Rated Current A:648
Open type Dimension(L*W*H) mm:3200*1310*1850
Open type Weight Kg::4250
Manufacturer:Cummins
Model:KTA19-G2
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA47.2S5
Excitation:Brushless, AVR
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

437KVA Cummins diesel generator KTA19-G2-60Hz

generating sets
437KVA generating sets KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
generating sets
437KVA generating sets KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms437PV
Product Name:437KVA generating sets -60Hz
Model:KTA19-G2
Prime Power(kw/Kva):350/437
Standby Power(kw/Kva):385/480
Rated Current A:648
Open type Dimension(L*W*H) mm:3200*1310*1850
Open type Weight Kg::4250
Manufacturer:Cummins
Model:KTA19-G2
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA47.2S5
Excitation:Brushless, AVR
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

437KVA Generating units KTA19-G2-60Hz

generating sets
437KVA generating sets KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
generating sets
437KVA generating sets KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms437PV
Product Name:437KVA generating sets -60Hz
Model:KTA19-G2
Prime Power(kw/Kva):350/437
Standby Power(kw/Kva):385/480
Rated Current A:648
Open type Dimension(L*W*H) mm:3200*1310*1850
Open type Weight Kg::4250
Manufacturer:Cummins
Model:KTA19-G2
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
ManufacturerLeroy Somer
Leroy Somer ModelLSA47.2S5
Excitation:Brushless, AVR
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

438KVA Cummins diesel generating sets KTA19-G3-50Hz

generating sets
438KVA generating sets KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms438PV
Product Name:438KVA generating sets -50Hz
Model:KTA19-G3
Prime Power(kw/Kva):350/438
Standby Power(kw/Kva):410/513
Rated Current A:648
Open type Dimension(L*W*H) mm:3400*1266*1830
Open type Weight Kg::3800
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

438KVA Generating unit KTA19-G3-50Hz

Generating unit
438KVA Generating unit KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms438PV
Generating unit
438KVA Generating unit KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms438PV
Product Name:438KVA generating sets -50Hz
Model:KTA19-G3
Prime Power(kw/Kva):350/438
Standby Power(kw/Kva):410/513
Rated Current A:648
Open type Dimension(L*W*H) mm:3400*1266*1830
Open type Weight Kg::3800
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

438KVA Generating units KTA19-G3-50Hz

generating sets
438KVA generating sets KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms438PV
generating sets
438KVA generating sets KTA19-G3-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms438PV
Product Name:438KVA generating sets -50Hz
Model:KTA19-G3
Prime Power(kw/Kva):350/438
Standby Power(kw/Kva):410/513
Rated Current A:648
Open type Dimension(L*W*H) mm:3400*1266*1830
Open type Weight Kg::3800
Manufacturer:Cummins
Model:KTA19-G3
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

438KVA Marine Cummins generator KTA19-G3M-50Hz

Marine Cummins generator
438KVA Marine Cummins generator KTA19-G3M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms438PVM
Marine Cummins generator
438KVA Marine Cummins generator KTA19-G3M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms438PVM
Product Name:438KVA Marine generating sets -50Hz
Model:KTA19-G3M
Prime Power(kw/Kva):350/438
Standby Power(kw/Kva):410/573
Rated Current A:630
Open type Dimension(L*W*H) mm:3100*1266*1830
Open type Weight Kg::3400
Manufacturer:Cummins
Model:KTA19-G3M
Exhaust19
Continuous/StandbyKW):403/448
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :203
Fuel consumptionL/h:93
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

43KVA Cummins diesel generator 4BTA3.9-G2-50Hz

generating sets
43KVA generating sets 4BTA3.9-G2-50Hz
use:Land
Frequency Hz:50Hz
generating sets
43KVA generating sets 4BTA3.9-G2-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms43PV
Product Name:43KVA generating sets -50Hz
Model:4BTA3.9-G2
Prime Power(kw/Kva):34/43
Standby Power(kw/Kva):38/48
Rated Current A:54
Open type Dimension(L*W*H) mm:1940*820*1490
Open type Weight Kg::1100
Manufacturer:Cummins
Model:4BTA3.9-G2
Exhaust3.9
Continuous/StandbyKW):55/60
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:17
Fuel consumption g/kw.h :213
Fuel consumptionL/h:16
Lub-oil Capacity Litre 14.2
max oil temperature 121
Coolant Capacity Litre 19.2
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S25
Stamford Model BCI184J
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

43kw Marine diesel generator 4BTA3.9-GM47-50Hz

Marine diesel generator
43kw Marine diesel generator 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms43pm
Marine diesel generator
43kw Marine diesel generator 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms43pm
Product Name:43kw Marine generating sets -50Hz
Model:4BTA3.9-GM47
Prime Power(kw/Kva):43/54
Standby Power(kw/Kva):48/60
Rated Current A:81
Open type Dimension(L*W*H) mm:15001640*750*1190
Open type Weight Kg::1370
Manufacturer:Cummins
Model:4BTA3.9-GM47
Exhaust3.9
Continuous/StandbyKW):47/52
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:16
Governor :E
Fuel consumption g/kw.h :209
Fuel consumptionL/h:11.9
Lub-oil Capacity Litre 10.9
max oil temperature 121
Coolant Capacity Litre 16.9
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Stamford Model UCM224F
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

0.45-0.7KW Portable Generator

Generator
Rated:0.65KW,Max:0.7KW
2.0HP Engine
Best Quality Crank Case with the weight of 4.96KG
Cast iron Cam Shaft
Generator
Rating frequency(Hz)
50
60
50
60
50
60

Rating Voltage(V)
110/120/220/230/240

Rating power(KVA)
0.45
0.55
0.65
0.75
0.75
0.85

The Max.power(KVA)
0.60
0.70
0.80
0.90
0.90
1.00

Power factor
1.0

Engine
Type
IE45F

Category
Single crock, air-cooled, 2-stroke gasoline engine

Exclusion of cylinder(cm
3
)
63

The Max.output power(Kw/rpm)
1.5/3600

Start system
Recoil

Capacity of fuel tank (L)
4.0

Consumption of fuel(L/h)
0.57

Consecutive Working(h)
7

Noise (at7m)(dB)
62

Dimension
Set dimension(mm
3
)
360×315×315


Net weight(kg)
18
20
21

100kw Cummins marine genset

100kw Cummins marine genset
powered by Cummins marine engine and Stamford alternator,can get CCS,BV,DNV,ABS certificate.
100kw Cummins marine genset

1.Main technical data of genset
1.1
Model
CCFJ100J
1.2
Prime power
100KW
1.3
Prime voltage
230/400V
1.4
Speed
1500 rpm
1.5
Weight
1250kg
1.6
Overall dimension
2150×920×1350mm (just for reference)
2.Main technical data of engine
Cummins engine, 4 stroke. DC start. Come with sea water pump, heater exchanger and expansion water tank, open-cycle cooling.
2.1
Brand
CUMMINS
2.2
Model
6BTA5.9-GM120
2.3
Prime power
120KW
2.4
Governor type
Electronic
2.5
Configuration
4 cycle , 6 cylinder in line
2.6
Cooling method
By heater exchanger
2.7
Bore/Stroke
102×120 mm
2.8
Displacement
5.9 L
2.9
Starting method
Electric
2.10
Fuel consumption
212g/kw.h
3. Main technical data of alternator
Alternator is selected the new type brushless alternator designed by US Marathon Electric, which has a unique design, advanced structure, small size, light weight, excellent performance, reliable running and easy-to-use operation.
3.1
Brand
MARATHON
3.2
Model
MP-H-100-4
3.3
Prime power
100KW
3.4
Configuration
Brushless , self-exciting
3.5
Prime voltage
230V/400V
3.6
Frequency
50 HZ
3.7
Power factor
0.8(lagging)
3.8
Phase/wire
3 phase 4 wires
3.9
Isolation
H

440KVA Cummins generators KTA19-G2-60Hz

Cummins generators
440KVA Cummins generators KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms440PV
Cummins generators
440KVA Cummins generators KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms440PV
Product Name:440KVA generating sets -60Hz
Model:KTA19-G2
Prime Power(kw/Kva):352/440
Standby Power(kw/Kva):387/484
Rated Current A:648
Open type Dimension(L*W*H) mm:3620*1350*1970
Open type Weight Kg::3600
Manufacturer:Cummins
Model:KTA19-G2
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Leroy Somer ModelLSA47.2 S5
Stamford Model HCI444FS
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

440KVA generating sets KTA19-G2-60Hz

generating sets
440KVA generating sets KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms440PV
generating sets
440KVA generating sets KTA19-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms440PV
Product Name:440KVA generating sets -60Hz
Model:KTA19-G2
Prime Power(kw/Kva):352/440
Standby Power(kw/Kva):387/484
Rated Current A:648
Open type Dimension(L*W*H) mm:3620*1350*1970
Open type Weight Kg::3600
Manufacturer:Cummins
Model:KTA19-G2
Exhaust19
Continuous/StandbyKW):336/369
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:83
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Leroy Somer ModelLSA47.2 S5
Stamford Model HCI444FS
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

440KW Perkins Diesel Generator Set 2506A-E15TAG2

* Good structure
* Reliable performance
* Easy maintenance
* Low exhaust
* Long period maintenance

* Good structure
* Reliable performance
* Easy maintenance
* Low exhaust
* Long period maintenance



GENERATOR SET
Genset model

Standby power (KW/KVA)

Prime power (KW/KVA)

Net Wet(kg/Open)

Packing Size(L*W*H, mm, open type)

DIESEL ENGINE
Engine brand & Model

Rated. output(kw/1500rpm)

Rated Output(KW/1800rpm)

Governing method
Mechanical/electric
Aspirated
Turbocharged
Cylinder number

Bore*stroke

Capacity of lubrication
8.5L
Fuel Consumption
≤205g/kw.h
Starting method
Electric start
Cooling method
Closed water cooled
ALTERNATOR
Alternator brand & model
Stamford/Leroy Somer/China reputed brand
Type
Brushless & self-excited
No. of phase
3
Voltage
220/380/400/440V
Frequency
50/60HZ
Power Factor
0.8
Insulation Grade
H
Protection Grade
IP22/23
Altitude
≤1500m

440kw Cummins gensets KTA19-G4-50Hz

Cummins gensets
440kw Cummins gensets KTA19-G4-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms440s
Cummins gensets
440kw Cummins gensets KTA19-G4-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms440s
Product Name:440kw generating sets -50Hz
Model:KTA19-G4
Prime Power(kw/Kva):400/500
Standby Power(kw/Kva):440/550
Rated Current A:772
Open type Dimension(L*W*H) mm:3400*1266*1830
Open type Weight Kg::4000
Manufacturer:Cummins
Model:KTA19-G4
Exhaust19
Continuous/StandbyKW):448/504
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:110
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

440kw Marine diesel generating sets KTA19-G4M-50Hz

Marine generating sets
440kw Marine generating sets KTA19-G4M-50Hz
use:Marine
Frequency Hz:50Hz
Marine generating sets
440kw Marine generating sets KTA19-G4M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms440sm
Product Name:440kw Marine generating sets -50Hz
Model:KTA19-G4M
Prime Power(kw/Kva):400/500
Standby Power(kw/Kva):440/550
Rated Current A:772
Open type Dimension(L*W*H) mm:3100*1266*1830
Open type Weight Kg::3700
Manufacturer:Cummins
Model:KTA19-G4M
Exhaust19
Continuous/StandbyKW):448/504
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:104
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

440kw Marine generating sets KTA19-G4M-50Hz

Marine generating sets
440kw Marine generating sets KTA19-G4M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms440sm
Marine generating sets
440kw Marine generating sets KTA19-G4M-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms440sm
Product Name:440kw Marine generating sets -50Hz
Model:KTA19-G4M
Prime Power(kw/Kva):400/500
Standby Power(kw/Kva):440/550
Rated Current A:772
Open type Dimension(L*W*H) mm:3100*1266*1830
Open type Weight Kg::3700
Manufacturer:Cummins
Model:KTA19-G4M
Exhaust19
Continuous/StandbyKW):448/504
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :6
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :159×159
Compression Ratio:13.9
Governor :EFC
Fuel consumption g/kw.h :196
Fuel consumptionL/h:104
Lub-oil Capacity Litre 50
max oil temperature 121
Coolant Capacity Litre 91
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 528
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)1050
Rated capacityV)24

44KVA Marine generating 4BTA3.9-GM47-50Hz

Marine generating sets
44KVA Marine generating sets 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
Marine generating sets
44KVA Marine generating sets 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms44PVM
Product Name:44KVA Marine generating sets -50Hz
Model:4BTA3.9-GM47
Prime Power(kw/Kva):35/44
Standby Power(kw/Kva):39/49
Rated Current A:63
Open type Dimension(L*W*H) mm:15001560*750*1190
Open type Weight Kg::1110
Manufacturer:Cummins
Model:4BTA3.9-GM47
Exhaust3.9
Continuous/StandbyKW):47/52
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:16
Governor :E
Fuel consumption g/kw.h :209
Fuel consumptionL/h:9.5
Lub-oil Capacity Litre 10.9
max oil temperature 121
Coolant Capacity Litre 16.9
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Stamford Model UCM224D
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

44kw Cummins genset 4BTA3.9-G2-50Hz

Cummins genset
44kw Cummins genset 4BTA3.9-G2-50Hz
use:Land
Cummins genset
44kw Cummins genset 4BTA3.9-G2-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms44s
Product Name:44kw generating sets -50Hz
Model:4BTA3.9-G2
Prime Power(kw/Kva):40/50
Standby Power(kw/Kva):44/55
Rated Current A:72
Open type Dimension(L*W*H) mm:1940*820*1490
Open type Weight Kg::1100
Manufacturer:Cummins
Model:4BTA3.9-G2
Exhaust3.9
Continuous/StandbyKW):55/60
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:17
Fuel consumption g/kw.h :213
Fuel consumptionL/h:16
Lub-oil Capacity Litre 14.2
max oil temperature 121
Coolant Capacity Litre 19.2
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S35
Stamford Model UCI224D
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

Thursday, October 6, 2011

44kw Marine Cummins generating sets 4BTA3.9-GM47-50Hz

Marine Cummins generating sets
44kw Marine Cummins generating sets 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
Marine Cummins generating sets
44kw Marine Cummins generating sets 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms44sm
Product Name:44kw Marine generating sets -50Hz
Model:4BTA3.9-GM47
Prime Power(kw/Kva):40/50
Standby Power(kw/Kva):44/55
Rated Current A:72
Open type Dimension(L*W*H) mm:1500*750*1320
Open type Weight Kg::1000
Manufacturer:Cummins
Model:4BTA3.9-GM47
Exhaust3.9
Continuous/StandbyKW):47/52
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:16
Governor :E
Fuel consumption g/kw.h :209
Fuel consumptionL/h:11.9
Lub-oil Capacity Litre 10.9
max oil temperature 121
Coolant Capacity Litre 16.9
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

44kw Marine diesel generating sets 4BTA3.9-GM47-50Hz

Marine diesel generating sets
44kw Marine diesel generating sets 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
Marine diesel generating sets
44kw Marine diesel generating sets 4BTA3.9-GM47-50Hz
use:Marine
Frequency Hz:50Hz
YK Model::kms44sm
Product Name:44kw Marine generating sets -50Hz
Model:4BTA3.9-GM47
Prime Power(kw/Kva):40/50
Standby Power(kw/Kva):44/55
Rated Current A:72
Open type Dimension(L*W*H) mm:1500*750*1320
Open type Weight Kg::1000
Manufacturer:Cummins
Model:4BTA3.9-GM47
Exhaust3.9
Continuous/StandbyKW):47/52
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:16
Governor :E
Fuel consumption g/kw.h :209
Fuel consumptionL/h:11.9
Lub-oil Capacity Litre 10.9
max oil temperature 121
Coolant Capacity Litre 16.9
Cooling methodheat exchanger
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Excitation:PMG
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

100kw Diesel Generator

1.100kw Diesel Generator
2.12 months warrenty
3.Reliable quality & comepetitive price
4.CE approval generator
100kw Diesel Generator:
Engine types: 4 cylinder, water-cooled and vertical 4-stroke
Frequency: 50Hz/60Hz
Maximum AC output: 110kVA
Rated AC output: 100kVA
Rated AC voltage: 230/400 and 120/240V
Fuel: direct light fuel
Oil: SAE (above CC grade)
Ignition system: direct injection
Starting system: electric
Overall dimensions: 2,980x 1,150 x 1,990mm.

44kw generator 4BTA3.9-G2-50Hz

generating sets
44kw generating sets 4BTA3.9-G2-50Hz
use:Land
Frequency Hz:50Hz
generating sets
44kw generating sets 4BTA3.9-G2-50Hz
use:Land
Frequency Hz:50Hz
YK Model::kms44s
Product Name:44kw generating sets -50Hz
Model:4BTA3.9-G2
Prime Power(kw/Kva):40/50
Standby Power(kw/Kva):44/55
Rated Current A:72
Open type Dimension(L*W*H) mm:1940*820*1490
Open type Weight Kg::1100
Manufacturer:Cummins
Model:4BTA3.9-G2
Exhaust3.9
Continuous/StandbyKW):55/60
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1500
Bore & Stroke mm×mm :102×120
Compression Ratio:17
Fuel consumption g/kw.h :213
Fuel consumptionL/h:16
Lub-oil Capacity Litre 14.2
max oil temperature 121
Coolant Capacity Litre 19.2
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 S35
Stamford Model UCI224D
Output Voltage V :400/230
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

44kw generator 4BTA3.9-G2-60Hz

generating sets
44kw generating sets 4BTA3.9-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms44s
generating sets
44kw generating sets 4BTA3.9-G2-60Hz
use:Land
Frequency Hz:60Hz
YK Model::kms44s
Product Name:44kw generating sets -60Hz
Model:4BTA3.9-G2
Prime Power(kw/Kva):40/50
Standby Power(kw/Kva):44/55
Rated Current A:72
Open type Dimension(L*W*H) mm:1940*820*1490
Open type Weight Kg::1100
Manufacturer:Cummins
Model:4BTA3.9-G2
Exhaust3.9
Continuous/StandbyKW):55/60
Aspiration & Cooling:Turbo/Aftercooled
Cylinders Capacity Lt :4
Cylinders & Build :In line
Speed RPM :1800
Bore & Stroke mm×mm :102×120
Compression Ratio:17
Fuel consumption g/kw.h :213
Fuel consumptionL/h:16
Lub-oil Capacity Litre 14.2
max oil temperature 121
Coolant Capacity Litre 19.2
Max intake resistancekPa)6.2
Max exhaust back pressure10
Flue gas temperature 502
Thermostat82-93
Leroy Somer ModelLSA43.2 M45
Stamford Model BCI184J
Output Voltage V :480/277
Steady Voltage Adjusting Range:±1%
InsulationH
ProtectionIP23
Ventilation cooling capacity1/s)216
Rated capacityV)24

450-10kw Portable generator GF2500C

Portable generator
1)CE and EPA approved
2)High efficiency
3)low fuel consumption
Portable generator

Model
GF1500C
GF2500C
GF3500C
GF4500C(E)
GF5500C(E)
GF6500C(E)
GF8000C(E)
type
Revolving Magnetic Field,single phase
AC Frequency(Hz)
60
50
60
50
60
50
60
50
60
50
60
50
60
50
AC Output volatge(V)
110;120;110/220;120/240,220;230;115/230
Cont.AC Output(VA)
1000
900
2200
2000
2800
2500
3300
3000
4500
4000
5500
5000
6500
6000
Max.AC Output(VA)
1500
1000
2500
2200
3500
2800
4500
3300
5500
4500
6500
5500
7000
6500
DC Output(V/A)
12/8.3
Engine Model
GF154F
GF168F
GF170F
GF177F
GF188F
GF188F(E)
GF190F(E)
type
Single cylinder,air-cooled ,4-stroke OHV
Starting System
Recoil
Recoil/Electric
Fuel Tank Capacity(L)
6
15
25
Packing Dimensions(mm)
450*365*355
605*435*450
690*520*570
720*530*580
Net Weight(kgs/lbs)
28/61.7
45/99.2
47/103.6
68/150
80/176.4
83/183
83/183
Per 20'GP CNT
432
239
132
125
per 40'GP CNT
912
490
292
250
Diesel generator
Model
GF2500J(E)
GF3500J(E)
GF5500J(E)
type
Revolving Magnetic Field,single phase
AC Frequency(Hz)
60
50
60
50
60
50
AC Output volatge(V)
110;120;110/220;120/240,220;230;115/230
Cont.AC Output(VA)
2200
2000
3000
2800
5000
4500
Max.AC Output(VA)
2500
2200
3500
3000
5500
5000
DC Output(V/A)
12/8.3
Engine Model
GF170F(E)
GF178F(E)
GF186F(E)
type
Single cylinder,air-cooled ,4-stroke
Starting System
Recoil/Electric
Fuel Tank Capacity(L)
7.5
13.5
15
Packing Dimensions(mm)
650*470*542
690*470*562
750*485*607
Net Weight(kgs/lbs)
65
45/99.2
47/103.6
Per 20'GP CNT
144
108


per 40'GP CNT
288
300


450-625KVA Soundproof Generator

Cummins Soundproof Generator
360-500KW/450-625KVA prime power
Engga/Marathon/Stamford alternator option
ISO9001:2008
Soundproof Generator
Silent generator/dieselgenerator/soundproof generator
1.Diesel engine CCEC Cummins K Series
2.Rated Power:360-500KW/450-625KVA
3.Soundproof type with base fuel tank for 8 hours operation
4.Electronic speed governing
5.Manual/Auto start
6.Automatic Transfer Switch is for optin



Power Specifications

1) 1500RPM at 50Hz/1800RPM at 60Hz
2) Water Cooled
3) Turbocharged

Electrical Specifications

1) Power Factor: 0.8 Lagging
2) 3 Phase 4 Pole
3) Insulation: Class H
4) Brushless
5) Self-Excited
6) IP22 Protection
7) AVR regulation
8) Starting by Battery

Special Specifications
1. Frequency: 50/60Hz
2. 3 Phase 4 Wire or 1 Phase 2 Wire
3. Speed: 1500/1800rpm
4. Three Phase Voltage Available: 208V / 220V / 230V / 240V / 380V / 390V / 400V / 415V / 440V / 460V / 480V
Single Phase Voltage Available: 100-250V

Manufacturing Standards:
ISO8528; ISO1105; ISO3046; GB/T2820; GB755; BS5000; NEMAMG-22; YD/T502

Electrical Parameters
Wave distortion: <10%
Voltage fluctuation: <0.5%
Voltage / frequency fluctuation: <=0.5%
AVR self-regulated, voltage regulation rate: <=+- 1%
Radio interference restraining accords with stipulation of VDE0875-N and ISO8528

Control Function
Key start / auto start
Monitoring meters: Current; Frequency; Wire Voltage; Genset KVA; Genset KW; Output
Capacity; Output KW.H; Power Factor.
Warning/Shutdown: Alternator Under/Over Volts, Frequency; Under/Over Speed; Low Oil Pressure; High Engine Temp; High/Low Battery Volts; Over Current; Earth
Fault Shutdown.


SHX Soundproof Generator Set Features:
A new kind of acoustic material is used as pugging, noise reducing
return-flow wind tunnel is used as generator set's ventilation system,
and louver is installed in the window to prevent rains and other intruders. High
efficiency silencer with double level structure and another silencer between two
levels keep the noise at the lowest level. The box is modular structure with indicator
and maintenance doors which make installation, operation and maintenance
very convenient. Benefited from the special design, medium low noise diesel generator
set's noise can be as low as 70dB (A) (at LP7m). Fuel tank can be installed
on it according to customer needs.

If you are interested in any item of them,please don't hesitate to contact us.