Wednesday, July 20, 2011

10 KW DIESEL SILENT GENERATOR SET

1.Silent, low noise (about 70 dB / 7m)
2.Compact structure with strong output power (lightest and smallest among the diesel gen
diesel generator set

Model
WS15000LTA3
Rated frequency (Hz)
50 60
Rated output power (kVA)
13 14
Max. power (Kva)
15 15.5
Rated voltage (V)
400/230 416/240
Rated current (A)
18.8 19.5
Phase No.
Three
Power factor
0.8lag
Insulation
F
Pole No.
2
Exciting way
Brush, exciting-self voltage-constant with AVR
Panel type
Intelligent
Output socket
Three-phase socketsingle-phase socket
DC12V output
12V, 8.3A
DimensionsL×W×H mm
1040×660×740
Net weight Kg
245
Noise 7mdB(A)
70
Structure type
Fully closed
Engine model
R2V870
Type
V-twin, two-cylinder, four-stroke, DI
Cylinder No. bore ×stroke (mm)
2-88×72
Total displacement (ml)
870
Rated power kW/ rated speed r/min
13/3000 14/3600
Compressed ratio
20:1
Cooling way
Air-cooled
Lubricating way
Pressure & splashing
Starting way
Electric
Fuel used
0summer-10winter-35cold winterlight diesel
Oil used
SAE10W30CD grade above
Lubricating oil capacity (L)
1.7
Starting motor capacity (V-kW)
12V 1.4kW
Dynamo capacity (V-A)
12V 8.3A
Battery capacity (V-Ah)
12V 45AH
Fuel consumption (g/kW.h)
≤298 ≤320
Fuel tank capacity of the generator (L)
21
Continuous operation time of the generator (H)
6.5 6
Features
1. Comparing other generators with same output, it is of compact structure, light weight and reliable performance.
2. Adopting the technique of new patented design structure
Aadopt the technique of new patented design structure to separate fully cold & heat wind passages in inner housing. It makes the generator output be no power drop for long-period operation.
The wind passage with special labyrinth design makes the generator be of lower noise.
3. Application of intelligence control panel
Adopt new-type intelligence control panel, which facilitate the operation. The operator can know the real working condition of the generator from panel reading. There are more than ten protections of the generator in the panel, such as protections of frequency, voltage, current, low oil pressure, low fuel level, and electric fan adjusting the temperature automatically when inner-housing temperature over 60, and automatic unload before engine stopped each time etc. The diesel/water separator can ensure the fuel quality.
4. Application of automatic shifting switch (ATS)
We can fit ATS based on customer requirement, which can make the generator be automatic operation without the operator on the spot. When city power net breaks down, ATS can deliver the signal in shortest time to the generator for starting. When city power net is recovered, ATS can shift the power from the generator to city power net and the generator will be automatically stopped later.
5. Application of new-generation intelligence AVR
Adopt new-generation intelligence AVR (automatic voltage-constant) to make the output voltage be steady.

No comments: