Monday, August 1, 2011

Diesel Generator

Diesel Generator
1)Engine:Cummins engine
2)Rated Power:20kw-1000kw
3)230/400v, three phase
4)50Hz/60Hz
Diesel Generator
Cummins Diesel Genset
1.Equiped with Chinese famous brand CUMMINS engine
2.LSG series brushless alternator designed by our own company and Leroysomer, also can use WUXI Xinshidai generator and Stanford HCI series brushless alternator
3.Alternator and diesel engine connected with coupling made of flexible plate,has tighten structure.
4.All in one struture,put the control box on the top of alternator, easy for assembly, small volume.
5.Normal type(GF) genset with whole set of meters to watch high water tempreture,low oil pressure,over speed and short cut protection.
6.Automatic type(GFZ) genset,all the readings can get from LCD which assemblied on it. The functions as following
-Four operating modes: Automatic, Running,Stop,Test running.
-Under automatic mode: genset will automatic start, reducing voltage, closing a main switch cotrol signals when the city electricity fail; After city electicity comes back, the genset will open the main switch; genset will be in standby situation.
-With communications, and includes RS485 intelligent communications interface, enables the remote control unit (remote control, remote) function;
-With over speed, less speed, low oil pressure, high water temperature, generator abnormal voltage, the flow of guns and start sensor fault protection failure, low-voltage fault alarm
7.Optional accessories
-RS232/RS485 Intelligent communication interface, and the three remote control for genset(remote control, remote, telemetry)
-Fu Chong battery device
-Genset / City electricity automatically switch screen
-Automatic, Manual parallel control screen
-Fuel tank

Cummins Diesel Genset Technical Sheet
(20KW-150KW, The data of other rated power see products list)
SETS
Model
300GF
(Z)
360GF
(Z)
400GF
(Z)
420GF
(Z)
460GF
(Z)
500GF
(Z)
500GF
(Z)
600GF
(Z)
728GF
(Z)
800GF
(Z)
1000GF
(Z)
330GF
(Z)-L
396GF
(Z)-L
440GF
(Z)-L
462GF
(Z)-L
506GF
(Z)-L
550GF
(Z)-L
550GF
(Z)-L
660GF
(Z)-L
800.8GF
(Z)-L
880GF
(Z)-L
1100GF
(Z)-L
Continous
Power (kw)
300
360
400
420
460
500
500
600
728
800
1000
Standby
Power (kw)
330
396
440
462
506
550
550
660
800.8
880
1100
Rate
Voltage
V

Rate
Frequency
Hz

Continous
Current (A)
541.3
649.5
721.7
757.8
830
902.1
902.1
1082.5
1313.5
1443.4
1804.2
Standby
Current (A)
595.4
714.5
793.9
833.6
913
992.3
992.3
1190.8
1444.9
1587.7
1984.6
Rate Power
Factor
Cos

Connection
Way

Fuel
Consume
g/kWh
210
205
203
203
210
212
212
214
214
202
197
Outside
dimension
3475
x1250
x1970
3500
x1250
x1970
3570
x1250
x1970
3570
x1250
x1970
3620
x1920
x2280
3620
x1920
x2280
4600
x1900
x2600
4770
x1900
x2600
4770
x1900
x2600
5010
x1900
x2600
5510
x1900
x2600
(LxWxH)
mm
Net Weight
kg
4100
4170
4300
4350
4600
4800
8000
9200
9500
10500
11050
ENGINE
Type
KTA
19-G2
KTA
19-G3
KTA
19-G4
KTAA
19-G5
KTAA
19-G6
KTAA
19-G7
KT
38-G
KTA
38-G2
KTA
38-G2A
KTA
38-G5
KTA
50-G3
Bore×Stroke
159mmX159mm
Rate RPM
( r/min)
1500
Starting
model
Electric
Starting and
Control
Voltage
24VDC
Governor
Model
Electric
ALTERNATOR
Type
Ff brandFuzhou Leloysomer LSA(China USA joint venture)MP(China UK joint venture)STFQianHui TFW three phase alternator
Excitation
Brushless Excitation
Insulation
H
Protection
IP23
Votage Regulation
AVR

Note:
1.Diesel generating sets standards in the light of national standards GB/T2820-1997 and ISO8528 international standards or requirements GJB235A-97, rated power (PRP) for the basic power; rated power (LSP) limit for standby power.

No comments: