Tuesday, September 6, 2011

8KW-160KW Ricardo diesel generator

1) Ricardo engine, stable perforance
2) 50/60 Hz, 400/230V AC 3phase
3) AMF& ATS
4) Slient,mobile, container, canopy type
Generator Model
SH8-160GF
Prime
Standby
Generator power(KVA)
200
220
Generator power(KW)
160
176
Engine power(KW)
184
Rated current(A)
289.6
Engine model
Ricardo 6126ZLD
Engine type
water-cooled, in line, 4-stroke, 6-cyliner, direct injection, Turbocharged
Governing method
Electric governer
Starting method
Electrical
Displacement (L)
8.35
Fuel consumptions (L/h)
40.5
Alternator model
TFW2-160
Exciting method
Brushless
Rated power factor
0.8 LAG
Connect method
three-phrase & four-wire
Regular
AVR Automatic voltage regulating
Insulation class
H
Protection class
IP23
Dimensions(L* W*H)(mm)
3240*1100*1800
Gross weight(kg)
2450
Packed volume(CBM)
6.5


ADDITIONAL INFORMATION
The Sound Compress Level is 75dB at 7 metres
All ratings are in accordance with CE and OQS-ISO9001-2000
ii. All ratings are based on nominal 400/230V, 3ph, 50Hz/60Hz
iii. Ratings are based on the original supplied test data under NTP ambient conditions.
iv. Fuel consumption figures are based on 100% prime ratings in accordance with the engines published data.
v. The above generating set kVA figures are based on a power factor of 0.8.
vi. The above alternator is Brushless excitation and "H" class insulation.
vii. The above generating set's Control Panel:
Key switch (manual type) control panel
Shock resist is fitted between control panel and generator set. Loose sheet is also fitted. The equipments of
control panel are Meters with Voltmeter,Ammeter,Frequency list,Water thermometer,Oil pressure gauge,Hour meter.
Control parts:
Start/stop key switch, start button, emergency stop button, voltage regulation
resistance, speed regulation resistance. Voltage phase switch ,Electric current phase selecting switch.
2. Protection setting for engine
For emergency shut down, overfeed, high water temperature, low oil pressure.
When some accidents appear, The digital Protector can shut down immediately, giving the battery voltage alarm and DC electrical source alarm. European extremity, steady wiring, and it can easily dismantle and install
3. The above generating set fitted with a base fuel tank for more than 8 hours using.

THE ABOVE QUOTATIONS' PERIOD OF VALIDITY: 6 MONTH.
Technical Power reserve the right to amend details and specifications without notice in line with our policy of continuous product development.