50/60HZ Cummins genset
Engine:Cummins
Alte:Leroy semor,Stamford or Marathon
Power:200kw-1000kw
Water-cooled
50/60HZ Cummins genset
Genset ,Cummins,
Features:
Technical Specifications and of Diesel Generator Set:
Techinical data
Genset model
GCW
Genset output Power range
20KW~1000KW
Rated Voltage
220/380V, 23/400V, 240/415V, 120/240V
Frequency
50/60Hz
Power Factor(COS)
0.8
Rated Speed
1500/1800RPM
Output Type
AC Three Phase/Singe Phase
Motor
Brushless
Diesel Engine
Brand
Cummins
Model
4B,4BT,6BT,6CT,NT,KTA
Engine Structure
6V-12V/6L-16V
Cooling Method
Water cooled
Rotating Speed
1500/1800RPM
Governor System
Electrical or Mechanical Governor
Aspiration mode
Natural aspirated or Turbocharged
Starting method
12/24V DC electric starting
Displacement(L)
/
Stroke
4 stroke
Compression Ratio
/
100%load fuel consumption(L/h)
/
Alternator
Brand
Leroy semor, Stamford, Meccalte, Maraton etc.
Model
Regulator
AVR automatic voltage regulating
Excite Type
PRET or Shunt
Connecting Type
3PH star,3PH-DELTA
Steady Frequency Change
0~5%
No load voltage
≥95%~105
Steady voltage
≤±1
Insulation degree
H degree
Exclosure degree
IP 23
The components of the genset
(1)Diesel engine;(2)Generator ;(3)Control panel
The Accessories
Wave pipe,curved pipe,muffler,accumulator and the connecting line,shock-absorbing spacer, and data.
Control panel
The control panel is GZ6110 control panel,one controller, a key power switch,a DC power indicator,Emergency button,
According to customers requirment , can provide ammeter, voltmeter,frequency tables, etc,
Built-in the fine-tuning knob of speed and voltage,
Can be configured according to customer requirements or pre-warm the engine oil button.
Other features:
Voltage available:
50hz:200/115,220/127,220/110,230/115,240/120,380/220,400/230,415/240(200v--690v)
60hz:480//277,440/254,220/127,240/139,208/120,120/240
Specifications:
1.engine:
a) single or three phase,4 storke
b)water cooling
c)Direct combustion chamber
d)Supercharging internal cooling
e)Integrated high intensity cylinder
2.Alternator:
a)Excitation mode: Brushless
b)Regulator: automatic regulator
c)Voltage deviation:+_0.5%
d) Insulation: Class H
e)Protection: IP23
3.Control system:
a)Automatic alarm system: the unit has the acoustic-optics alarm system and arrestor for any situation as the start defeat, the water is over temperature the oil pulls down, over speed, over load and over current
b) Operation display:
i)Unit voltage, tri-phase load current and frequency display
ii)Water temperature, oil pressure display
iii)Fuel level, fuel temperature dieplay
iv)Audible and visual alarm lamps and buzzers
4.Starting system: DC alternator is used to start engine
5.Short circuit protection:MCCB ari switch
6.Cooling system: combined cooling water tank fittled to meet the requirement of radiation at ambient temperature
7.Filter system: oil, fuel and air filter
8.Accessories: exhaust elbow, bellow, muffler
9.Supply standard collocation:
a)Diesel engine with all accessories, 3 filter, electric systems
b)Alternator
c)Steel structure
d)Fan and water tank cooling system
e)Flange connector
f)12/24 V starting motor and charge engine
g)Air cleaner, fuel cleaner, oil cleaner
h)On-board control panel
i)MCCB air conservation switch
j)12/24V starting accumulator and Battery line
k)Set shock absorber
l)High-efficient silencerlnner
Keywords: Cummins generator, generator set, generator, power generator,diesel generator, diesel generator set , power generator set, water-cooled generator, genset,CUMMINS generator, Chongqing cummins generator,burshless generator set,Cummins diesel generator,Cummins diesel engine,Cummins diesel generator set,diesel engine generator,Cummins power generator,Cummins power generator set,diesel gen-set, diesel genset,
No comments: