Saturday, September 10, 2011

8-10KW gensent set

Portable silent diesel generator set, patent product
Technical Data:generator set
Model
WS12000LTA
Rated frequency Hz
50 60
Rated output power kVA
10 11
Max. power kVA
11 12
Rated voltage V
230 240
Rated current A
43.5 45.8
Phase No.
Single
Power factor cosφ
0.9(lag)
Insulation
F
Pole No.
2
Exciting way
Brush, exciting-self voltage-constant with AVR
Panel type
Intelligent
Output socket
Single-phase socket, wiring terminal
DC12V output
12V, 8.3A
DimensionsL×W×H mm
1040×660×740
Net weight Kg
245
Noise 7mdB(A)
70
Structure type
Fully closed
Engine model
R2V840
Type
V-twin, two-cylinder, four-stroke, DI
Cylinder No. bore ×stroke mm
2-86×72
Total displacement ml
836
Rated power kW/ rated speed r/min
11/3000 12/3600
Compressed ratio
20:1
Cooling way
Air-cooled
Lubricating way
Pressure & splashing
Starting way
Electric
Fuel used
0#(summer)-10#(winter)-35#(cold winter) light diesel
Oil used
SAE10W30
(CD grade above)
Lubricating oil capacity L
1.7
Starting motor capacity V-kW
12V 1.4kW
Dynamo capacity V-A
12V 8.3A
Battery capacity V-Ah
12V 45AH
Fuel consumption g/kW.h
≤298 ≤320
Fuel tank capacity of the generator L
21
Continuous operation time of the generator H
7 6.5


Shining Points:
The lightest and smallest among the gensets with same outpout
Full automatic generator protection system
Special dual protection system
Unique unloading system for stopping the generator
Steady frequency-governing ratio ≤ 3%, complying with military standard
Automatic Voltage Regulation for maintaining steady voltage
Automatic transfer switching,remote monitoring, to realize guardless by human
Low noise,only 70dB/7m
New patent design,low inner housing temperature,stable output and good reliability
Features:
1. Comparing other generators with same output, it is of compact structure (1100*660*740mm), light weight (248kg)and reliable performance.
2. Adopting the technique of new patented design structure
Our company has adopted the technique of new-patented design structure to separate fully cold & heat wind passages in inner housing. It makes the generator output be no power drop for long-period operation.
The wind passage with special labyrinth design makes the generator be of lower noise.
3. Application of intelligent control panel
Our company has adopted new-type intelligent control panel, which facilitate the operation. The operator can know the real working condition of the generator from panel reading. There are more than ten protections of the generator in the panel, such as protections of frequency, voltage, current, low oil pressure, low fuel level, and electric fan adjusting the temperature automatically when inner-housing temperature over 60, and automatic unload before engine stopped each time etc. The diesel/water separator can ensure the fuel quality.
4. Application of automatic shifting switch (ATS)
Our company can fit ATS based on customer requirement, which can make the generator be automatic operation without the operator on the spot. When city power net breaks down, ATS can deliver the signal in shortest time to the generator for starting. When city power net is recovered, ATS can shift the power from the generator to city power net and the generator will be automatically stopped later.
5. Application of new-generation intelligent AVR
Our company has adopted new-generation intelligent AVR (automatic voltage-constant) to make the output voltage be steady.