Friday, September 2, 2011

AOSIF Deutz water-cooled diesel Generator with CE and ISO

1. Power:100kv water-cooled diesel generator
2.Engine:TD226B-6D
3.Alternator:LSA 44.2VS45
4.Controller:Deepsea,Comap
5.MCCB
100kva Deutz water-cooled diesel generator

Genset Model
A80
Prime Power(50HZ)
80KW / 100KVA
Standby Power(50HZ)
88KW / 110KVA
Frequency/Speed
50Hz/1500rpm
Voltage
230V/400V
Phases
Three phases, four wires

Engine:

Manufacturer
Weifang Weichai Deutz Diesel Engine Co.,LTD
Model
TD226B-6D
Engine Configuration
6-cylinder in line,4storke,Exhaust gas turbocharged, direct spray fuel system
Displacement
6.23 L
Engine Cooling Mode
The radiator suitable for 40°C temperature,strap drive the cooling fan with protection cover
Speed control panel
Mechanical speed controller,electricity-magnet valve conrol switch
Start mode
24V Direct Current Start,including alternator&battery
Engine Filter System
Dry air filter type,Fuel filters,Lube filter
Compression Ratio:
16.0:1
Bore and Stroke:(mm)
105×120
100%Load fuel consumption (L/h)
20.8
Specific fuel consumption (g/kwh)
≤205
Lubricating oil consumption (g/kwh)
≤1.36
Exhaust Air Flow (m3/min)
90
Air consumption
6
Exhaust gas Flow(m3/min)
14.5
Exhaust gas Temperature(°C)
480
Oil Capacity(L)
13
Coolant Capacity(L)
25.8

Alternator:

Manufacturer / Model
Leroy-somer Electro-technique (Fuzhou) Company Ltd.
Model
LSA44.2 VS45
Output power
84KW
AVR model
R250
Number of phase
3
Power factor (Cos Phi)
0.8
Altitude
≤ 1000 m
Overspeed
2250RPM
Number of Pole
4
Exciter type
Shunt
Insulation class
H
Voltage regulation
±0.5%
Sustained short circuit current
300% (3 IN) : 10s
Total harmonics (TGH/THC)
<2 %
Wave form : NEMA = TIF
< 50
Wave form : I.E.C. = THF
< 2%
Bearing
single
Coupling
Direct

No comments: