Saturday, July 30, 2011

Diesel generator LF3500E 2011 new type

Diesel generator LF3500E chooses reason:
1.Custom products
2.OEM service
3.Small order accepted
4.Reasonable price
Diesel generator LF3500E product details
1. Data & Standard
generator parameters
Model
LF3500E
Generator
Frequency (Hz)
50
60
Max. AC output (kW)
3
3.6
Rated AC output (kW)
2.8
3.3
DC output (V-A)
12/8.3
Rated voltage (V)
230
240 / 120
Power factor
1
Phase
Single - Phase
Excitation system
Transistorized self-excitation
Engine
Model
GEGO178FG
Type
Single-cylinder, vertical,air-cooled, direct-injection
Displacement (cc)
296
Rated output (P/rpm)
5.5 / 3600
Fuel tank capacity
15
Lube. oil capacity
1.1
Operational capacity
12 hours
Others
Dimensions (LxWxH)mm
640 x 480 x 530
NW/GW (kg)
85/88
Certificate
CE/GS/RoHS
Qty/20’ GP
144 sets
Petrol Portable Generator Enterprise standard
accepted standard
executed standard
English title
ISO 780:1997
GB/T 191-2000
Packaging-Pictorial marking for handling of goods
ISO 8528-8:1995
GB/T 2820.8-2002
Reciprocating internal combustion engine driven alternating current generating sets--Part 8:Requirements and tests for low-power generating sets
ISO/IEC GUIDE 37,NEQ
GB 9969.1-1998
General principles for preparation of instructions for use of industrial products
ISO 1680.1-86,REF
GB 10069.1-1988
Measurement of airborne noise emitted by rotating electrical machinery and the noise limits--Engineering method for the measurement of airborne noise

GB/T 13306-1991
Plates
IEC 533,REF
GB/T 14024-1992
Limits and methods of measurement of radio interference characteristics of electric power plant with internal combustion engines-Conducted interference

GJB 1488-1992
Military electric power plant with internal combustion engines general method of tests
ISO 8528-1993
JB 8587-1997


JB/T 10304-2001
Gasoline generating sets of 50Hz technical conditions

2. Detail pictures


3. Products
The appearance of all kinds of generators could be changed properly with major structure unchanged. The generators are powered by LF170F, LF178F, LF186F, F186FA, LF188F diesel engine, and could be added electric start according to your various demands. The function of control system could be extended properly, brush generator and brushless generator are the two choices for you, different type of sockets and control panels can be installed for your different requirements. If you have some special requirements, Please tell us in advance.

4. Small Tips
1. During the operation of generator set, the exhaust gas contents some compound of CO and CH. In order to avoid accident, the generator must not be used inside of the room, if it has to be used inside the room, the exhaust gas must be led to the outside of the room and the outlet of the guide pipe must be not less than 1m form the doors & windows, meanwhile, the air in the room must be free from inhibition.
2. The inflammable, explosive and any other dangerous substances must be far away from the ac alternator, the air in the working place must be free from inhibition. The fire source must be not less than 10m away from the engine; what’s more, the generator must lie in the wind direction of the fire source.
3. When filling in fuel & lubricating oil, the generator must be stopped, smoking is not allowed, if the fuel or lubricating oil overflows or leak out, thoroughly clean it before the engine is started.
4. The operators must be specially trained. The persons who are not qualified to operate the Generator are strictly forbidden to operate this Diesel Generator.





No comments: