GF2 Series Three-Phase Diesel Generating Sets

GF2 Series Three-Phase Diesel Generating Sets
1)Already approved by ISO9001:2000
2)CE IEC
3)Voltage: 400v/230v
GF2 Series Three-Phase Diesel Generating Sets
THE FORMATION INSTRUCTIONS OF DIESEL GENERATING SETS
1. Diesel generating sets
all diesel generating sets include diesel engine, alternator and control box and all the alternators have been made by Fujian Fuan Gangfa Electrical Machinery Co, Ltd.
2. Starting method of gen-sets.
a).manual switch
b).automatic starting wholly: when electric supply has been stopped, the gen-sets can start three times automatically in 3-28seconds(time can be adjustable)between electric supply and everytime need 6-8seconds.lt will spend 12 seconds to accept load when electric supply is resumed, gen-set will maintain 23-230 seconds, then closes down automatically.
3. Control system
Apparatus: voltmeter, frequency meter, amperage meter, voltmeter, voltmeter of battery, meter of water temp., oil meter. control section; starling handler, key type switch, inductive type self-protection switch, and indicator.
Technical Data

Gen-sets Model
Rated Output
(KW)
Rated Current
(A)
Fuel consumption
(g/kw.h)
Starting method
Engine model
Dimension (mm)
N.W. (Kg)
GF2-3kW
3
5.4
≤280.2
S180
950×470×550
150
GF2-5kW
5
9
≤258.4
S195G S195GNM
1350×620×760
280
GF2-7.5kW
7.5
13.5
≤250.3
S195G S1100
1350×620×760
310
GF2-10kW
10
18.1
≤257
12V D.C
295AD
1380×640×1000
600
GF2-12kW
12
21.6
295AD
1380×640×1000
600
GF2-15kW
15
27
395AD
1640×650×980
650
GF2-20kW
20
36
495AD
1780×750×1000
750
GF2-24kW
24
43.3
495AD
1780×750×1000
780
GF2-30kW
30
54.1
495AZD
1820×750×1000
920
GF2-40kW
40
72.1
≤238
24V D.C
4135D
2200×710×1900
1610
GF2-50kW
50
90.2
4135D
2280×720×1350
1750
GF2-64kW
64
115.4
*4135D
2400×850×1400
1800
GF2-75kW
75
135.3
*6135
2400×850×1400
2330
GF2-90kW
90
162.3
*6135D
3000×900×1370
2500
GF2-100kW
100
180.3
*6135AD
3000×900×1370
2650
GF2-120kW
120
246.5
≤238
*6135AZD
3000×900×1370
2800
GF2-150kW
150
270.6
≤250
*12V135D
3300×960×1650
3500
GF2-200kW
200
360.8
≤250
812V135AD
3210×1320×1920
3750
GF2-250kW
250
451
≤250
*12V135D
3210×1320×1920
1850
GF2-300kW
300
541.2
≤250
W12V135AZD-1
3300×1770×1905
4300
GF2-320kW
320
277.3
≤228
W12V135AZL
3300×1770×1905
4350
Note*Voltage: 400v/230v
Note*Rotation speed: 1500/1800r.p.m/min
Note*Cooling method: closed circulation cooling
Note*Frequency: 50Hz 60Hz
Note*Power factor: 0.8(LAG)
Note*Triple harmonic STC series or brushless exciting or TFW series of alternator