Saturday, August 27, 2011

Boomaster Leading diesel generator set

diesel generator set
1.engine: Cummins
2.Alternator: Stamford/Leroysomer
3.70dB @ 7 meters
4. 12 months warranty
diesel generator set
Boomaster Leading diesel generator full descriptions as below:

Genset Model
Prime Power
Standby Power
Engine Model
Fuel Consumption
(g/kwh)
Net Dimension
Net Weight
(kg)
KW
KVA
KW
KVA
BC16
16
20
18
22.5
4B3.9-G
≤229
1800*800*1200
650
BC20
20
25
24
30
4B3.9-G
≤229
1800*800*1200
700
BC24
24
30
28
35
4BT3.9-G
≤214
2000*800*1200
800
BC30
30
38
35
43.5
4BT3.9-G
≤214
2000*800*1200
800
BC40
40
50
45
56
4BTA3.9-G
≤215
2000*800*1200
900
BC56
56
70
64
80
6BT5.9-G
≤215
2200*960*1400
950
BC70
70
88
80
100
6BT5.9-G
≤215
2400*960*1400
1100
BC80
80
100
85
106
6BT5.9-G
≤215
2400*960*1400
1200
BC96
96
120
106
133
6BTA5.9-G2
≤215
2400*960*1400
1300
BC104
108
135
118
148
6BTAA5.9-G2
≤215
2400*960*1400
1450
BC120
120
150
132
165
6CTA8.3-G2
≤210
2600*1060*1700
1680
BC145
145
181
160
200
6CTA8.3-G2
≤210
2600*1060*1700
1790
BC160
160
200
180
225
6CTAA8.3-G2
≤210
2900*1100*1800
2000
BC200
200
250
220
275
6LTAA8.9-G2
≤210
2900*1100*1800
2250

Specifications:
1 Output range: 20KW-200KW
2 Available Engine: Cummins
3 Alternator model:
a) Stamford\Leroy Somer\ENGGA\Branch Stamford and Branch Leroysomer
4 Small volume, light weight, low noise, low fuel consumption, water cooling
with water tank and fan\air cooling
5 Key start / auto start
6 Monitoring meters and control switches
7 Protection provided for short, over-current, over-speed, high water temperature
and low oil pressure
8 Soundproof / weatherproof canopy optional
9 Standard parts: industrial type silencers, exhaust pipes, flexible exhaust bellows,
vibration-damping rubber, lead-acid batteries, connective cables, user manual
and technical papers

Control system:
1 a) Automatic alarm system: the unit has the acousto-optics alarm system and arrestor for any situation as the start defeat, the water is over temperature, the oil pulls down, over speed, over load and over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
2 Starting system: DC alternator is used to start engine
3 Short circuit protection: MCCB air switch
4 Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40°C
5 Filter system: oil, fuel and air filter
6 Accessories: exhaust elbow, bellow, muffler

Supply standard configure:
a) Diesel engine with all accessories, 3 filter, electric systems
b) Alternator
c) Steel structure
d) Fan and water tank cooling system
e) Flange connector
f) 12 / 24V starting motor and charge engine
g) Air cleaner, fuel cleaner, oil cleaner
h) On-board control panel
i) MCCB air conservation switch
j) 12 / 24V starting accumulator and Battery line
k) Set shock absorber
l) High-efficient silencer

Parameters:
1) Rated voltage: 400 / 230V, 220/127V
2) Rated Frequency: 50Hz/60Hz
3) Mode of connection: 3-phase-4-line
4) Rated power factor: 0.8 (lagging)
5) Wave distortion: <10%
6) Power supply voltage: 24V
7) Voltage fluctuation: <0.5%
8) Voltage / frequency fluctuation: ≤0.5%




No comments: