Friday, August 26, 2011

CCFJ CUMMINS SERIES MARINE DIESEL GENERATOR SETS

Allowed parallel connection of two or above normal marine gensets for stable operation and power transfer without stopping
Rated Power:
Rated power means the continually-running power under fluctuated load. Overloading of 10% is allowed for 1 hour every 12 hours. Rated power as per the nominal indication. Optional for 60 Hz diesel gensets, air-starting diesel gensets, marine emergency diesel gensets.
main components for generating sets:
Alternator: Lanzhou genertor, Marathon, or Stamford with F or H insulation grade optional for equipment according to the customers requirements.
Parellel connection: Allowed parallel connection of two or above normal marine gensets for stable operation and power transfer without stopping.
Protective Function: For heavy-duty gensets, monitoring system equipped for tracking oil temperature, water temperature, oil pressure, and running speed under control.
Genset Model
CUMMINS SERIES DIESEL ENGINE FOR GENERATOR
Generator
Size and weight
Diesel Model
Rated Power/Speed(KW/r/min)
Piston strokemm
Fuel consumption at rated working condition(w.h)
Intake way
Generator Model
Overall dimension(L×W×H)MM
Net weight of gensetkg
CCFJ-30
4B3.9-D
37/1500
4-102×120
210
Natural aspiration
SB-HW6-30
2080×770×1200
980
CCFJ-40
4BT3.9-D
46/1500
4-102×120
210
Turbo-charged
SB-HW6-40
2080×770×1200
1060
CCFJ-50
6BT5.9-D
54/1500
6-102×120
210
Natural aspiration
SB-HW6-50
2210×770×1200
1100
CCFJ-64
6BT5.9-D
78/1500
6-102×120
210
Turbo-charged
SB-HW6-64
2210×770×1200
1200
CCFJ-100
6CT8.3-D
122/1500
6-114×135
210
Turbo-charged
SB-HW6-100
2400×800×1370
1650
CCFJ-120
6CTA8.3-D
164/1500
6-114×135
210
Turbo-charged inter-cooled
SB-HW6-120
2400×800×1370
1700
CCFJ-200
NTA855-G1
240/1500
6-140×152
210
Turbo-charged inter-cooled
SB-HW6-200
2850×980×1750
3080
CCFJ-250
NTA855-G2
283/1500
6-140×152
206
Turbo-charged inter-cooled
SB-HW6-250
2900×980×1750
3180
CCFJ-300
KTA19-G2
336/1500
6-159×159
206
Turbo-charged inter-cooled
SB-HW6-300
3150×1000×1960
3750
CCFJ-350
KTA19-G3
403/1500
6-159×159
206
Turbo-charged inter-cooled
SB-HW6-350
3200×1000×1960
3860
CCFJ-400
KTA19-G4
448/1500
6-159×159
206
Turbo-charged inter-cooled
SB-HW6-400
3250×1000×1960
3970
CCFJ-500
KT38-G
560/1500
12-159×159
206
Turbo-charged inter-cooled
SB-HW6-500
3950×1220×2600
6200

No comments: