Friday, August 19, 2011

Cummins 50Hz three phase diesel generator (25kVA to 1000kVA)

1.Cummins 50Hz three phase Diesel Generator
2.25kva to 1000kva
3.Cummins engine
4.Marathon alternator
5.water cooled
Cummins 50Hz three phase diesel generator (25kVA to 1000kVA)
PFC SERIES PARAMETER 50Hz
No.
Genset Model
Output Power
Engine Model
Fuel Consumption(L/H)
Size(Open Type)
Weight
KVA
KW
Diesel
Lub. Oil
L*W*H mm
KG
1
PFC25
25
20
4B3.9-G2
5.1
0.03
1620*710*1200
560
2
PFC38
38
30
4BT3.9-G2
7.7
0.04
1670*710*1200
630
3
PFC56
56
45
4BTA3.9-G2
10.3
0.05
1730*710*1225
680
4
PFC93
93
75
6BT5.9-G2
19.2
0.10
2120*830*1290
1020
5
PFC112
112
90
6BTA5.9-G2
23.0
0.12
2170*830*1340
1120
6
PFC125
125
100
6BTAA5.9-G2
25.6
0.13
2210*830*1355
1160
7
PFC150
150
120
6CTA8.3-G2
30.7
0.15
2290*850*1360
1180
8
PFC183
183
146
6CTA8.3-G2
37.1
0.18
2380*850*1360
1220
9
PFC200
200
160
6CTAA8.3-G2
41.0
0.20
2510*940*1550
1280
10
PFC250
250
200
6LTAA8.9-G2
46.0
0.05
2650*950*1600
2210
11
PFC313
313
250
MTAA11-G3
58.3
0.07
2650*1000*1500
2250
12
PFC344
344
275
NTA855-G2A
65.8
0.08
2900*1000*1700
2850
13
PFC375
375
300
NTAA855-G7
71.8
0.08
2960*1400*1700
2920
14
PFC450
450
360
KTA19-G3
84.0
0.09
3200*1250*1800
3580
15
PFC500
500
400
KTA19-G4
93.3
0.11
3300*1250*1800
3620
16
PFC625E
625
500
KTAA19-G5
105.0
0.13
3300*1800*1950
3760
17
PFC688E
688
550
KTAA19-G6A
116.7
0.14
3300*1950*2240
3810
18
PFC750
750
600
KTA38-G2
140.0
0.16
4250*1650*2200
6500
19
PFC800
800
640
KTA38-G2A
146.3
0.17
4250*1650*2200
6600
20
PFC910
910
728
KTA38-G2A
169.9
0.20
4300*1650*2200
6650
21
PFC1000
1000
800
KTA38-G5
186.7
0.22
4380*1900*2300
6800
1) Output range: 25kva to 1000kva
2) Engine model: 4BTA3.9-G, 6BT5.9-G, 6BTA5.9-G, 6BTAA5.9-G,
6CTAA8.3-G, NTA855-G, KTA19-G, KTAA19-G, KT38-G, KTA38-G, KTA50-G
3) Alternator: Stamford, Leroy Somer, Marathon series
4) Water-cooled,
5) 8hrs operation base tank,
6) Key start / auto start,
7) Sound-proof / weather-proof canopy is optional
8) 230 / 400V AC, 50Hz, 0.8pF three-phase and four wires
alternating current output
9) Frequency: <3%
10) Frequency at stable state: <0.5%
11) Frequency deviation at instantaneous state: ≤+10%
12) Frequency return time: ≤3s
13) Voltage deviation at stable state: ≤±1%
14) Voltage deviation at instantaneous state: ≤+20%
17) Standard configuration of gensets:
a) Engine:
Cummins diesel engine
b) Engine type: water-cooled, in line four-stoke, Humit cylinder liner,
direct injection
c) Alternator:
Faraday or Stamford brushless alternator
18) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
19) Starting system: DC alternator is used to start engine
20) Short circuit protection: MCCB air switch
21) Cooling system: combined cooling water tank fitted to meet the
requirement of radiation at ambient temperature 40°C
22) Filter system: oil, fuel and air filter
23) Accessories: exhaust elbow, bellow, muffler
24) Supply standard collocation:
a) Diesel engine with all accessories, 3 filter, electric systems
b) Alternator
c) Steel structure
d) Fan and water tank cooling system
e) Flange connector
f) 12 / 24V starting motor and charge engine
g) Air cleaner, fuel cleaner, oil cleaner
h) On-board control panel
i) MCCB air conservation switch
j) 12 / 24V starting accumulator and Battery line

No comments:

Post a Comment