Thursday, August 18, 2011

Cummins Diesel Genset

1. Cummins Diesel Genset
2. Prime Power: from 1Kw-2000Kw
3. ISO9001:2000;ISO14001:2004
Cummins Diesel Genset
1. Cummins Diesel Generator Manufacturer,
2. Oil and fuel filter fitted, water separator, Lube-oil drain valve fitted
3. Electric starter & Charge alternator 24 V D.C.
4. Mechanical governor
5. Normal duty air filter

Voltage Regulation

Maintains voltage output to within ±1.0%.
At any power factor between 0.8 and 1.0
At any variations from No load to Full load.
At any variations from Cold to Hot.
At speed droop variations up to 4.0%.

Frequency Regulation
Isochronous under varying loads from no load to 100% full load when electronic
governor is fitted.

Random Frequency Variation
Will not exceed ±0.5% of its mean value for constant loads – no load to full load.

Waveform
Total harmonic distortion open circuit voltage
waveform in the order of 1.5%. Three-phase

balanced load in the order of 5.0%.

Telephone Influence Factor (TIF)
,
TIF better than 50.
THF to BS 4999 Part 40 better than 2%.

Alternator Temperature Rise
Class H insulation. Allow 125 C temperature rise

Radio Interference
In compliance with BS 800 and G,N levels of VDE

No comments:

Post a Comment