Friday, September 30, 2011

50HZ 1500R Pekins(Lovol)gensets(22KW-112)

50HZ 1500R Pekins(Lovol)diesel gensets
1.Power output:25KW-112KW
2.Optional color,1 year warranty
3.AC 3ph4wr,0.8lagging
Pekins(Lovol)diesel gensets
Output range:
25KW-112KW
Engine model:
1003G,1003GT,1004TG,1006TG1A,
1006TG2A,1006TAG
Alternator:
Stamford,Marathon
Diesel engine model:
1003GT
Characters:
Water-cooled,4-stroke,inline,
dry sylinde liner,direct injection
Constant output:
30KW/37.5KVA
Aspiration:
Turbocharged
Bore(mm)*Stroke(mm):
105*120
Cubic capacity(Liters):
6.23
Piston speed(m/s):
6
Compression ratio:
16.0:1
Machine governor:
≤5%
Electric governor:
≤1%
Acoustic pressure(dba):
≤110
Exhaust tempreture:
≤550
Lube capacity:
13
Cooling system volume:
27L
Rating fuel consumption(l/h):
27.1
beautiful appearance design
high reliability
low in fuel consumption
convenient operation,reasonable prices
Details:
1) Output range: 18kW (24kVA) - 112kW (140kVA) ,
2) Engine model: 1003G, 1004G, 1004TG, 1006TG1A, 1006TG2A, 1006TAG ,
3) Alternator: Stamford, Leroy Somer, Marathon series ,
4) Water-cooled,
5) 8hrs operation base tank ,
6) Key start / auto start ,
7) Sound-proof / weather-proof canopy is optional ,
8) 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four wires alternating current output
9) Frequency: <3% ,
10) Frequency at stable state: <0.5% ,
11) Frequency deviation at instantaneous state: ≤+10%
12) Frequency return time: ≤3s
13) Voltage deviation at stable state: ≤+ -1% ,
14) Voltage deviation at instantaneous state: ≤+20% ,
15) Voltage return time: ≤4s ,
16) Voltage modulation: ≤0.3%
17) Standard configuration of gensets:
A) Engine: Perkins diesel engine ,
B) Engine type: Water-cooled, in line four-stoke, dry cylinder liner, direct injection
C) Alternator: Brushless and "H" class insulation
18) Control system:
A) Automatic alarm system: The unit has the acousto-optics alarm system and
Arrestor for any situation as the start defeat, the water is over temperature,
The oil pulls down, over speed, over load and over current
B)
Operation display
:
I) Unit voltage, tri-phase load current and frequency display
Ii) Water temperature, oil pressure display
Iii) Fuel level, fuel temperature display
Iv) Audible and visual alarm lamps and buzzers
19) Starting system: DC alternator is used to start engine
20) Short circuit protection: MCCB air switch
21) Cooling system: Combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40 degree
22) Filter system: Oil, fuel and air filter
23) Accessories: Exhaust elbow, bellow, muffler
24) Supply standard collocation:
A) Diesel engine with all accessories, 3 filter, electric systems
B) Alternator
C) Steel structure
D) Fan and water tank cooling system
E) Flange connector
F) 12 / 24V starting motor and charge engine
G) Air cleaner, fuel cleaner, oil cleaner ,
H) On-board control panel
I) MCCB air conservation switch
J) 12 / 24V starting accumulator and battery line
K) Set shock absorber
L) High-efficient silence

No comments: