Monday, August 15, 2011

Cummins diesel generator set 32KW/40KVA 50HZ 1500RPM

HONNY POWER Diesel generator set,Cummins engine, 1500RPM, 50Hz,Rated power 32KW/40KVA,Rated voltage 400/230V adjustable
HCM44 diesel generator Specification -50Hz

Generator set
Genset Model
HCM44
Rating Power (KW/KVA)
32/40
Standby Power(KW/KVA)
26/32.5
Rating Ammeter(A)
58
Diesel engine
General data
Engine model
4BT3.9-G
Prime Power(KW/KVA)
36/45
Standby Power(KW/KVA)
40/50
number of Cylinder & Configuration
4 cylinders in line
Bore X Stroke (mm)
102X120
Displacement(l)
3.9
Compression Ratio
16.5:1
Governor type
Mechanic
Rated RPM
1500
Exhaust system
Exhaust gas flow(m³/min)
11
Max. Exhaust Gas Temperature(°C)
520
Max. Exhaust back Pressure(KPA)
10
Air intake system
Aspiration Type
Turbocharged
Max. intake depression(KPA)
6
Combustion air Volume(m³/min)
2.8
Fuel system
Rating Fuel Consumption(l/h)
7.2
75% full Fuel Consumption(l/h)
7.5
Lubrication system
Total oil capacity(l)
9
Max permissible oil temp(°C)
121
Oil pressure at rated rpm(KPA)
345-413
Cooling system
Total Coolant capacity(l)
18
Max. temperature of coolant(°C)
96
Fan cooling air flow(m³/min)
125
Alternator
Alternator model
MGA225-32-4S
Rating Voltage(V)
400/230
Rating Capacity(KW/KVA)
32/40
Eff.%
86.4%
Power Factor
0.8
Exciting type
Brushless self-exciter, AVR
Voltage regulation
±1%
No. of Phase
3 phase 4 wire
Enclosure Class
IP21
Class of Insulation
H
Battery
Rating Capacity(AH)
2X80AH 12V
Dimension
Generator set dimension (LXWXH)
1600X830X1300
Weight
Generator set Net Weight (kg)
1000


Specification data sheet


Performance Feature
·Engine and alternator shall be mounted on a same frame steel skid.
·Built-in damper for anti-vibration.
·Small size, low weight, easy to operating, installation and maintenance.
·World most famous brand diesel engine.
·World famous brand AC alternator: Stamford, Marathon, Leroy Somer, MVC.
·Advanced and reliable control module: Key start, Auto start, Remote control by PC with RS232/485
·Full range protect function and alarm shutdown feature.

Alternator Feature
·Brush-less, 4 poles, rotation magnet.
·IP21-23(NEMA1) enclosure is standard for all industrial alternators.
·The insulation system is Class H
·Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts.
·Wide range of flange adaptors and single bearing disc coupling.
·Standard 2/3 pitch windings avoid excessive neutral currents
·AVR auto voltage regulator, auto exciter, auto adjustment

Standard Accessory
Common steel base frame, Circuit breaker, Damper, Exhaust silencer, Flexible pipe, Battery and connecting wires, Operation manual and document.

Optional Accessory
Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & paralleling system, Soundproof Canopy and Moving Trailer.


ATS SYSTEM
For emergency power usage in building, Auto transfer switch (ATS) is essential. ATS can automatic transfer load from Mains power supplying to Emergency power. In normal, when the Main power supplying failure or voltage drop below 80% of normal voltage, ATS will auto start Emergency generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reach at rated speed, the ATS will transfer the load to emergency generator sets automatically